Waterproofing
Site Installation
2. Attach the LPU to the wall using wood or masonry screws (not included), via the 
holes as shown in 
3. Connect the left screw (where the grounding lug was located) to a ground source. 
4. Remove the cable glands. 
5. Thread the CAT‐5e/6 cables through the cable glands, and connect the cables to the 
LPU as shown in 
6. Tighten the cable glands around the CAT‐5e/6 cables as shown in 
7. Route one CAT‐5e up to the radio (via the upper LPU), and the other to the IDU or 
PoE. 
8. RADWIN recommends that you add extra waterproofing to the connections 
(see 
).
Figure 2‐61: Installing an LPU on a wall
2.2.9 Waterproofing 
Protect all connections between any outdoor devices and cables from rain, dust, moisture 
and salt according to the procedure below:  
1.  Use a high quality sealing material such as Scotch 23 Tape ¾” wide, to ensure IP‐67 
compliant protection against water and dust.
2. Cut two pieces each 25 cm long, of Scotch 23 splicing tape. Remove the plastic 
cover to expose the tacky side of the sealing tape as shown in 
.