The Interconnect Circuit Board provided on the (1550) unit is
equipped with diagnostic modes that will continuously monitor the
operation of the lift.  The Circuit Board has four available diagnos-
tic modes to accommodate all types of installations.
(The elevator is shipped in Mode #1)
Provides full range of Audio diagnostic notices:
* Circuit Board Power Up :  Chirp
* Safety Device Activated:  Chirp
* Stairlift Stopped off Charge Bumper:  5 Beeps (4 short and 1
long)  Repeats every 3 minutes until stairlift is returned to
bumper.
* Battery Voltage Drop :  5 Beeps (3 short and 2 long)  Repeats
every 4 minutes until seat safety switch is disengaged,  the
battery voltage increases or switch is pressed.
* Battery Voltage Critical:  5 Beeps (2 short and 3 long)
Repeats once a minute until voltage is above 16 V or switch is
pressed.
* Switch is active during Power Up:  2 Beeps / Pause Repeats
beeps every 5 seconds until all switches are off.
* More than one switch active:  2 Beeps / Pause Repeats every
30 seconds until all switches are off.
Provides the same audio diagnostic notices as Mode # 1 except
for the Seat Safety Disengaged notice.  The unit will chirp one
time and not repeat the notice.
In the quiet mode none of the Audible Warning Messages are
active.
Provides battery audio diagnostic only.
* Stairlift Stopped off Charge Bumper:  5 Beeps (4 short and 1
long)  Repeats every 3 minutes until stairlift is returned to
bumper.
* Battery Voltage Drop :  5 Beeps (3 short and 2 long)  Repeats
once every 4 minutes until seat safety switch is disengaged or
the battery voltage increases.
* Battery Voltage Critical:  5 Beeps (2 short and 3 long)
Repeats once a minute until voltage is above 16 V.
CIRCUIT BOARD OPERATION
MODE # 1 MULTI - USER / DIAGNOSTIC MODE
MODE # 2  SINGLE - USER
MODE # 3 QUIET
MODE # 4 BATTERY WARNINGS ONLY