© 1998 BRUNO INDEPENDENT LIVING AIDS, INC.
17
Chirp
.25 Seconds
Short Beep
.5 Seconds
Long Beep
1.5 Seconds
Pause
1 Second
CIRCUIT BOARD OPERATION
AUDIO  REFERENCE
CHANGING THE PCB DIAGNOSTIC MODE
* Turn the Circuit Breaker on the carriage to `OFF'.
* Remove Left carriage cover.
* Turn the Power DIP Switch (SW3) to the `OFF' position.
* Unit is shipped is Multi-User diagnostic Mode # 1.
Changes are
made on (S1) 4 Ganged DIP Switch -
Number 3 and Number 4 Positions.
Also located on S1 DIP Switch are switch #1 Installation and
#2 Coast Delay.  Refer to page 15 (Reversing operation) for
changing Switch # 1.  The coast delay option (Switch #2 on
S1) has been provided in cases of interference which may
cause intermittent operation.  The normal setting is 1.5 sec-
onds of coast, should the unit lose the remote call/send signal,
this can be increased to 2.0 seconds by moving switch # 2 on
S1 to the `ON' position.
4 GANGED DIP SWITCH (SW1)
DIAGNOSTIC MODE
DIP SWITCH POSITION
#3
#4
Mode
# 1 - Multi-User
OFF
OFF
Mode
# 2 - Single-User
OFF
ON
Mode
# 3 - Quiet
ON
OFF
Mode
# 4 - Battery Warning Only
ON
ON
OTHER CIRCUIT BOARD FEATURES