Make the connections to the Charger Wiring Harness.
[ ]
Route the Charger Wiring Harness along the back side
of the Rail and secure it to the Rail Mounting Clamps
with wire ties.  Be sure that this wiring is mounted
securely so that it is not vulnerable to physical damage.
[ ]
Coil any excess harness wire and attach to a Rail Clamp
(under the rail).
NOTE:  THE CHARGER SHOULD BE PLUGGED INTO A
HOUSEHOLD OUTLET ALL OF THE TIME.  THE ELEVATOR IS
DESIGNED SO THAT THE BATTERIES WILL BE CHARGED
WHEN THE CARRIAGE IS AT ONE OR THE OTHER END OF
THE RAIL.  IT IS IMPERATIVE THAT THE CARRIAGE BE
"PARKED" AT THE END OF THE RAIL WHEN IT IS NOT IN USE
TO MAINTAIN FULL BATTERY CHARGE.
IN AN INSTALLATION WHERE THE CARRIAGE CAN NOT BE
PARKED AT THE END OF THE RAIL (STAIRWAYS WITH A
DOOR AT THE TOP, FOR EXAMPLE), THE CARRIAGE
SHOULD BE RUN TO THE OTHER END  OF THE RAIL WITH
THE REMOTE CALL/SEND MODULE WHEN NOT IN USE.
THIS WILL ENSURE THAT THE BATTERIES WILL REMAIN
FULLY CHARGED.
FIGURE 17
SUGGESTION:
AFTER ROUTING THE
WIRE HARNESS OUT OF
SIGHT A SMALL PIECE
OF DOUBLE SIDED
FOAM TAPE CAN BE
APPLIED TO THE
HARNESS PLUGS AND
ATTACH  UNDER THE
RAIL.
NOTE:
 IF CHARGER PLUG AND
WIRE ARE LOCATED IN
A VULNERABLE
LOCATION, A PLUG
LOCK TO PREVENT
ACCIDENTAL
UNPLUGGING IS
RECOMMENDED.
THESE ARE AVAILABLE
AT HARDWARE AND
DEPARTMENT STORES.
RAIL CHARGER LEAD
LEAD TO BATTERY
CHARGER WIRING
HARNESS
ROUTING WIRE HARNESSES