Section 3  Engineering Guidelines
TRACER 6000 Series Split System Manual
 34
Copyright © 2005 ADTRAN, Inc.
612806320L1-1A
4.
REVIEWING THE TRACER 6200 REAR PANEL DESIGN
Figure 2 identifies the features of the TRACER 6200 rear panel, and Table 6 provides a brief description of 
each interface. 
Figure 2.  TRACER 6200 Rear Panel
Table 5.  Null-Modem Pinout 
Modem
Pin
TRACER
Pin
1 (CD)
Unconnected
2 (RXD)
3 (TXD)
3 (TXD)
2 (RXD)
4 (DTR)
6 (DSR)
5 (GND)
5 (GND)
6 (DSR)
4 (DTR)
7 (RTS)
8 (CTS)
8 (CTS)
7 (RTS)
9 (RI)
Unconnected
Table 6.  Rear Panel Description
1
1
Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.
Name
Connector
Description
A
Network Module 
Slots
N/A
Dual network module slots for system flexibility (shown with an 
E1 and Ethernet Switch module installed)
B
MGMT
RJ-45
10/100BaseT/TX Ethernet interface for SNMP, TFTP, and Telnet 
access
C
DC Power
Terminal block
21 to 60 VDC power source connection
D
Fuse
N/A
2A, 250 V, 2-inch slo-blo fuse
E
Alarm
Terminal block
External alarm monitoring system connection
F
Antenna
N-type
Antenna feedline cable connection
G
Ground Lug
N/A
Earth ground connection
To ODU
DC Power
Connection
Ground
Lug
Fuse
Alarm
Contacts
C
F
B
E
D
G
Ethernet
Interface
Network
Module Slots
A