Section 3  Engineering Guidelines
TRACER 6000 Series Split System Manual
 36
Copyright © 2005 ADTRAN, Inc.
612806320L1-1A
To ODU Interface (N-Type Connector)
The 
TO ODU 
interface (N-type connector) is the IDU-side IF connection between the IDU and ODU. The 
IDU transmits payload data to the ODU on a 280 MHz carrier and receives the ODU data on a 140 MHz 
carrier. The IF connection also provides a full-duplex control and monitoring channel between the IDU and 
ODU on a 4.5 MHz carrier. Additionally, this interface provides DC power to the ODU, taken directly 
from the voltage supplied to the power connection on the rear of the IDU. The power supply is protected 
from a short-circuit on the IDU/ODU connection via a thermal protection device.
5.
TRACER 6320 OUTDOOR UNIT (ODU)
Figure 3 identifies the features of the TRACER 6320 ODU bottom panel without the integrated antenna 
(Figure 4 on page 37 shows the system with the integrated antenna) and Table 10 on page 37 provides a 
brief description of each interface. 
Figure 3.  TRACER 6320 ODU Bottom Panel without Integrated Antenna
Table 9.  Alarm Contact Connector Pinout 
Pin
Name
Description
1
COM
Common Contact
2
NO
Normally-Open Contact
3
NC
Normally-Closed Contact
Antenna
Connector
A
GND
B
RSSI
C
Weather-proof
Cover for RSSI and GND
D
Connection
to IDU
E