Figure 21 on page 64 shows the T1x Performance History menu page, which displays detailed error 
statistics for the T1 link (from both the local and remote TRACER 6420 units) in 15-minute and 24-hour 
increments.
Figure 21.  T1x Link Performance History
T1 performance data is presented as Errored Seconds (ES) and Severely Errored Seconds (SES) on the T1 
interface. The following events qualify as an ES–AIS, LOS or LOF Alarm Second, a single BPV, 
excessive zero event, or a single parity bit. An SES is caused by an AIS, LOS or LOF Alarm Second, 
excessive BPVs, or framed parity bit errors causing a line bit error rate (BER) of 10
-6
.
The error counts for the most recent 24 hours are recorded in 15-minute increments and displayed on the 
right side of the page. The left side of the page displays the 24-hour totals for the most recent 7 days.
The following menus for the T1x Performance History apply to all four available T1 
interfaces (A through D).
Press <n> to view the next 8 hours worth of 15-minute totals and <p> to view the previous 
8 hours.
24 
Hours
Days
(8 Hrs 
Displayed 
at a Time)