Adtran TRC6420L2X Manual Do Utilizador

Página de 132
TRACER 6000 Series Integrated System Manual
Section 5  User Interface Guide
612806420L1-1E
Copyright © 2005 ADTRAN, Inc.
67
Figure 10.  RF Link Max/Min Received Power History
The received power level (
MIN 
and
 MAX
) represents the minimum and maximum values of received signal 
levels in 24-hour or 15-minute increments, and is displayed as a numerical value in dBm.
> RF L
INK
 M
IN
/M
AX
 R
ECEIVED
 S
IGNAL
 Q
UALITY
 H
ISTORY
Figure 10 on page 67 shows the TRACER 64x0 RF Link Min/Max Received Signal Quality History menu 
page, which displays the available received signal quality statistics from the system. Minimum and 
maximum received signal quality levels for the RF link (from both the local and remote TRACER 64x0 
units) in 15-minute and 24-hour increments are found on this menu page.
Real-time signal values are not supported on all TRACER 64x0 systems. Systems must be 
ADTRAN calibrated to provide readings for Rx or Tx Power signal levels. For 
uncalibrated systems, the received power level is displayed as a numerical value from 0 to 
100 where 0 corresponds to 0V RSSI and 100 corresponds to 5V RSSI.
The minimum receive power level is recorded to aid in troubleshooting problem RF links. 
Radio links with high 
MIN 
numbers and intermittent performance are probably 
experiencing interference, while links with low 
MIN 
numbers have improperly engineered 
paths or excess system losses. A system with 
MIN 
numbers varying widely could indicate 
fading, reflections, or an intermittent installation problem such as loose connectors, 
damaged coax or lightning arrestors, or water contaminated feedlines.
Press <n> to view the next 8-hour segment of 15-minute totals and <p> to view the 
previous 8-hour segment.
7
Days
24
Hours
(8 hours 
displayed 
at a time)