Troubleshooting
Check that all front and rear connectors and cables are in place, and that 
power switches are on. If problems persist, contact your regional 
Tait
 office.
Symptom
Possible Cause
Action
Alarm LED red and steady 
(not flashing)
The 
base station
 is in 
Offline mode
Use the web interface to put the 
base station
 in 
Online mode
Desired feature is not 
operating
Feature license missing
Check that you have the necessary feature licenses 
(refer to 
 and the Help)
Feature license present but 
feature is not enabled 
Use the web interface to enable the feature. 
Tx stuck on
Tx and Rx frequencies are 
the same
Reconfigure Tx and Rx with different frequencies
Power LED on front panel 
is on, but keypad does not 
work
Keypad is disabled
Check that the keypad is enabled in the web 
interface (Configure > Base Station > 
Miscellaneous) 
No power or LEDs on front 
panel
System control bus not 
connected to front panel
Check cable connections 
Pins bent on 15-pin 
D-range plug on front 
panel
Replace or repair D-range plug
The 
base station
 appears to 
make random 
transmissions
CWID feature enabled
No action: CWID transmissions are made according 
to configuration settings
PA has low power
Channel is configured to 
low power
Use the web interface to check the power settings
PA may have suffered 
partial damage
Replace module and send faulty module for 
servicing
Test tones can’t be heard
IMBE does not pass on 
tones higher than 400 Hz
Ensure test tones are less than 400 Hz
Lost or forgotten 
base 
station
 IP address
Procedure TBD
?
?