N. V. Nederlandsche Apparatenfabriek NEDAP SENSITEPL Manual Do Utilizador

Página de 92
SENSIT SYSTEM | MANUAL 
SENSIT Interface Software
 
 
58/92 
13.5.3  NODE PRESENCE 
This screen will display information on the last received message from each node present in 
the network. It will outline the Node ID, type number, version and the timestamp of the last 
received message. 
 
Node presence check (min) 
If a node does not respond within a certain time period after transmission of the last 
message, the SENSIT Server will check if the node is still available. In this menu option you 
can select the time after receiving the last message (in minutes) when to send the Node 
presence check. 
 
Node presence check retry
 
The 'Node presence check retry' specifies the number of times the SENSIT Server shall try 
to connect to the node. 
 
Figure 43: Node presence 
In the screenshot above several nodes are listed in the node cross check.  
For example node id 00.0000.72BC is a SENSIT IR (type 3109). Every different type of node 
has its own Type code, see below the general use types: 
Type code 
Node description 
000c 
Data Collector 
0018 
Relay Node 2G 
3003 
Relay Node 1G 
3109 
SENSIT Flush Mount or SENSIT IR 
310D 
SENSIT Flush Mount or SENSIT IR 
310E 
Electronic Parking License (EPL) 
8004 
WSN Display 
 
13.6  DEFINITION 
 
13.6.1  RELAY NODE CONFIGURATION 
You can click the Refresh button and verify if the Relay Node ID appears in the Current 
Relay Nodes list. 
Figure 44: Relay Node configuration screen