The mouthpiece or other components of the IntegraMouse Plus are not intended 
for any kind of sterilization, not even e.g. for sterilization with steam or gamma 
sterilization. 
9.2 
Cleaning the device 
Clean the device regularly, about once a week. The parts of the IntegraMouse Plus, 
mouthpiece, IM+ connect, power pack including cable and stand can be cleaned at any time 
by wiping with a damp, lint-free cloth. 
 
Never use sharp cleaning objects to clean the components as this could destroy 
the surface. The IntegraMouse Plus and IM+Connect contain sensitive 
electronics. Never immerse these components in water and also never use 
running water to clean them, otherwise you could destroy the device. 
 
 
In the clinical sector multiple use of the device by several users is forbidden. 
The re-use of the mouthpiece, the membrane or the silicon tube is also 
forbidden. Use these three components as disposable products and change 
them regularly after use, e.g. once a day. The other components should be used 
in accordance with the cleaning and disinfection plan.
 
 
Disinfection by wiping 
In special environments, e.g. hospitals, it is necessary to carry out regular disinfection by 
wiping the device. The IntegraMouse Plus can be disinfected with any surface disinfectant 
product that is intended for the disinfection of LEXAN polycarbonate and aluminum. Under no 
circumstances may any components of the IntegraMouse Plus be subjected to steam or 
water sterilization. 
 
The following cleaning products can be used: 
Mikrozid Sensitive liquid or Mikrozid Sensitive wipes from the company Schülke & Mayr 
GmbH (www.schuelke.com).  
Carry out the disinfection by wiping according to the manufacturer's instructions and ensure 
that no moisture seeps into the IntegraMouse Plus.