27.Power failure/recovery SMS alert
Power failure: 
the system will send SMS “External power supply is disconnected, running
on battery” and show L5 on the panel.
Power recovery: Send SMS“External power supply recovery” and show L6 on the panel.
Command: [*]→[0]→[5]→[A]→[*]
A=2, enable SMS alert for power failure and recovery
A=0, disable SMS alert for power failure and recovery
28.Disarm/Arm SMS response
User will receive SMS response when the system is disarmed or armed.
The SMS will be sent to the 1
st
of Group alarm number
Command: [*]→[9]→[A]→[*]
A=7, enable SMS response for armed and disarm operation
A=6,disable SMS response for armed and disarm operation
SMS response:“system is disarmed, home/away armed ”
29.Disarm/Arm programmed by SMS
User can send SMS command to arm the system remotely
SMS Command for Away arm:【password】+【SF】
Example: 【0000SF】
SMS Command for home arm:【password】+【BF】
Example: 【0000BF】
SMS Command for disarm:【password】+【CF】
Example: 【0000CF】
30.System status Query by SMS
User can send SMS command to check the system status remotely
SMS Command :【password】+【STATUS】
Example: 【0000STATUS】
31.12V voltage output start/stop by SMS
User can send SMS command to start or close the 12V voltage output at
the back of 12V terminal remotely
SMS Command to start 12V output:【password】+【ON】
SMS Command to stop12V output:【password】+【OFF】
Example: 【0000ON】and 【0000OFF】
32.Handling the call alarm
In case of alarm happened, system will make a call to user one by one.
Once the user answers it, firstly it will play pre-recorded alarm voice on
the call, after that, user can program the following command
Press “1” to listen in
Press “2” to start siren