1:Enable,upload alarm information, except for arm/disarm
information
0: Disable
2.System ID for CID setting via SMS
User can set unique ID for each system to work with CID protocol CMS.
This operation needs to set via SMS
SMS Command :【password】+【*】+【0】+【9】+【A】+【ID】+【*】
A= 4 digits
Example, if user wants to set 6868 as system ID for CID CMS, send SMS
0000*096868ID* to the system
3.Alarm code for CID protocol network station setting
CID defined that different alarm has its unique alarm code, so that CMS
will recognize the alarm type according to the code
Command: [*]→[0]→[9→[A]→[B]→[*]
A=zone number (3 digits required)
B=CID alarm code (3 digits required)
For example,[*]→[0]→[9→[002]→[110]→[*] , 002 means zone 2, 110 is the alarm code of
fire alarm, which is defined by CID protocol
Understanding for wire sensor connection
1.Enable/disable wire zone setting
User can disable or enable 4 pcs of wire zones as per the following
command. Default setting is disable
Enable Command: [*]→[0]→[6]→[1]→[*]
Disable command: [*]→[0]→[6]→[0]→[*]
2.Wire zone No/NC type setting
User can set the wire zones with normal open type or normal close type
as per the following command. (Default setting is normal open type)
Command: [*]→[9]→[A]→[B]→[*]
A=zone number from 101-104. 101 for L1, 102 for L2, 103 for L3, 104
for L4.
B=0/1/. 0: normal close. 1:normal open
Example: Require to set wire zone 103 to be normal close for wire door sensor, user can
press the command on the panel [*]→[9]→[103]→[0]→[*]
3.Wire sensor installation:
Take wire zone 104 with wire door sensor for example
Step 1: User need to enable the wire zone by command:[*]→[0]→[6]→[1]→[*]. The default
setting is disable wire zones
Step 2: Program wire zone 104 with NC type by command [*]→[9]→[104]→[0]→[*]. Note: