GSI ELECTRONICS INC. EDGERFID Manual Do Utilizador

Página de 70
Clearance around the KP-8IN-1REL, TP-8IN-1REL, TR-2IN-1REL
Figure 1-4 Minimum clearance
Correctly supporting and routing cables
Properly supporting and routing the cables helps avoid electromagnetic interference and wire damage.
Rigid conduits of up to 1 inch (25.4mm) can be used for connection to the P-8IN-1REL, TP-8IN-1REL,
TR-2IN-1REL.
NOTE: Nylon cable glands are permitted for cable or wire fastening.
WARNING
Use watertight compression cable glands rated IP66 for each cable used.
WARNING
Use silicone to seal the cable gland rated IP66 if more than one cable is used in the
same cable gland.
WARNING
The warranty is void if the product enclosures are not sealed correctly and the
installation does not respect the manufacturer recommendations.
WARNING
Ensure all cables enter through the bottom of the plastic enclosure. Do not make
holes on the top or on the sides of the enclosures. Be careful not to damage the
electronic cards located inside the enclosure when drilling at the bottom of the
enclosure.
NOTICE
The use of flexible tube with water and dust tight connectors at both ends is
acceptable.
Cable support
Support the cables with clips or cable trays whenever possible to avoid damage at the connection points.
895-00695