Putting into service a SECU-DATA 142xx
1. Connect the probes and the evaluation equipment to the SECU-
DATA 142xx units
2. Turn on the DC power supply
in the range of +11 V … +40 V
3. Match one pair of instruments together:
Set the same channel block number on both instruments
– factory
default is block #6
– details se chapter Settings-Selection of the
RF-channel block
Match the instruments together
Match the instruments together
– detail see chapter Settings-
Matching two SECU-DATA xxxx
4. Both SECU-DATA 142xx modules will establish an RF-inter-
connection immediately, the green RF-indicators are blinking. After
some seconds they are continuously on
some seconds they are continuously on
– the connection is active.
5. The current on the input of the SECU-DATA 142xM is reproduced
precisely on the output of the SECU-DATA 142xC for evaluation
with the controller equipment.
with the controller equipment.
6. Check the current values on the evaluation instrument for
plausibility.
The commissioning is completed now successfully.
Dismantling
Important:
If you detect any damage of the housing, controls, connection wires or other
connected devices, immediately disconnect the unit from the power supply.
If you cannot ensure the safe operation of the device, immediately shut
down the unit and the respective accessories, secure them against inad-
vertent switching on
If you detect any damage of the housing, controls, connection wires or other
connected devices, immediately disconnect the unit from the power supply.
If you cannot ensure the safe operation of the device, immediately shut
down the unit and the respective accessories, secure them against inad-
vertent switching on
, mark them clearly as “defective, out of order” and
send them in to an authorized service facility.