Settings 
Selection of the RF-channel block 
SECU-DATA  1xxxx  instruments  use  one  RF-channel  out  of  64.  These  are 
organized in 8 blocks with 8 channels each. The default setting is block #6. 
Two  SECU-DATA  1xxxx  instruments  are  able  to  communicate  only  if  the 
same block for RF-channels is set on both instruments. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Procedure for both units: 
1.  Open the housing of the SECU-DATA 1xxxx. Avoid the intrusion of 
moisture and pollution while the instrument is open to maintain the 
reliability 
2.  Turn on the power supply of the SECU-DATA 1xxxx 
3.  Press the B-button two times shortly 
4. 
The  green  “RF“-LED  will  blink  several  times,  the  number  of  light 
pulses gives the actual number of the channel block (1 to 8).  
5.  The light pulses are repeated after a 1 s pause. Each press on but-
ton  A  increments  the  block  number  by  1.  On  the  end  of  the  range 
the block number falls back from 8 to 1 automatically. 
6.  An interruption of the power supply aborts the procedure, the origi-
nal block number remains in memory; the actual one is not stored. 
7.  The procedure can be finished by pressing the B-button; the actual 
block number is stored permanently. 
8.  Repeat this procedure for the second SECU-DATA 1xxxx to set the 
same block number 
If required you may check the block number using steps 1 to 4 as described 
above.  
Button B 
Button A