Wiring of the SECU-DATA xxxx: 
1.  For the wiring use round wires of type: 0,08 
– 2,5mm
2
 cross section, 
AWG 28 
– 12, flame propagation characteristics as per IEC 60332-
1-2, within a round cable to ensure the water protection 
2.  Strip the wires off app. 5-6 mm 
3.  Depress each of the levers of the terminal block  (Type WAGO se-
ries 256) with a small screw driver 
4.  Put  the  stripped  wire  end  into  the  terminal  and  release  the  lever 
again 
5.  Close the SECU-DATA xxxx housing again and mount it to the final 
location with the supplied screws in the provided holes of the hous-
ing.  Take  care  for  correct  positioning  of  the  sealing  elements.  For 
metal  base  planes  ensure  that  there  is  some  space  between  the 
RF-antenna  and  the  metal  material  to  maintain  the  best  effective 
range of the RF connection. 
 
Remark:
 After delivery one cable gland is sealed waterproof with a cap. 
This is useful if only one cable gland shall be used.