PowerDsine PD-6006 Manual Do Utilizador

Página de 16
 
PD-6006/12/24
 
Power over LAN Solutions 
Cat. No.: 06-6800-056
2 About the Power over LAN Midspan 
PowerDsine’s family of Power over LAN Midspans, series 6000,  injects power 
over data-carrying Ethernet cabling. The PD-6006/6012/6024 Midspans, 
support 6, 12 and 24 ports respectively in a 10/100BaseTx Ethernet network, 
over TIA/EIA-568 Category 5/5e/6 cabling. DC operating power, for data 
terminal units, is fed over unused pairs of the cabling (7/8 and 4/5). 
The Power over LAN Midspan normally powers devices that are Power over 
LAN enabled or are equipped to receive power over Ethernet. These devices 
are called Powered Devices (PDs). Devices that are not equipped to receive 
power over Ethernet may require an external power adapter in order to be 
powered. Contact PowerDsine for such an adapter. 
Power over LAN Midspan main features: 
 
 
 
 
Remote power feeding of Ethernet terminals 
 
 
 
 
Eliminates the need for AC outlets, local UPS and AC/DC 
adapters 
 
 
 
 
Universal range power input (100-240 VAC, 50/60 Hz and/or 
46 to 57 VDC) 
 
 
 
 
Power management  
 
 
 
 
SNMP management (optional) 
 
 
 
 
Independent overload and short-circuit protection per channel 
 
 
 
 
Port status indications  
 
 
 
 
Standard 19-inch rack mountable. 
 
2.1 
Power Management  
When establishing a network, the total power required by PDs may exceed the 
total power available from the Midspan. The built-in Power Management 
feature will not allow the total power output to exceed the maximum power 
available (refer to the Technical Specifications). When the total power 
available is near maximum, attempts to connect an additional PD to a free port 
will cause the corresponding LED of the port to blink orange, indicating an out-
of-power budget. This port will not deliver power. Power distribution is based 
on “first come, first served” logic.  
It is possible that connected and operating PDs will significantly increase or 
suddenly raise their power requirements. If the power required exceeds the 
power available, the Power over LAN Midspan will start to turn off ports, 
starting from the last port down, until the total power is once again under the 
maximum limit.