Polycom Welding System 3725-77601-001H Manual Do Utilizador

Página de 560
 
System Troubleshooting
Polycom, Inc. 
535
 
Conference On Demand Problems and Solutions
Gatekeeper Cause Codes
Problem
Description
Solutions
Dialing a Conference On Demand 
fails.
Inviting other endpoints into a 
conference using the CON service 
fails.
The endpoint dials a CON service, 
and the call is rejected because of 
one of the following:
The MCU is not registered or is 
offline.
The CMA system cannot log 
into the MGC.
The MGC has no resource 
available for the call.
The MGC’s IP address is not 
entered in the CMA system.
Check the diagnostics log for an 
ARJ reason from this endpoint.
Verify that the MCU is 
registered with the CMA system 
and is online. 
Verify that the MCU registered 
with the CMA system has the 
MCU’s IP address filled out in 
the Devices list.
Verify that the MCU login ID and 
password for the CON service 
are correct. 
Verify that the H.323 network 
service that the MCU is using is 
set as the default service.
Verify that the MCU has enough 
available resources to start this 
conference. 
Verify that the CON service is 
enabled. Go to Admin > Dial 
Plan and Sites > Services
.
Cause 
Code
Description
150
The gatekeeper is out of resources
151
The gatekeeper has insufficient resources
152
The gatekeeper registration version is invalid
153
The call signal address is invalid
154
The registering device’s address is invalid
155
The registering device’s terminal type is invalid
156
The registering device’s permissions are invalid
157
The conference ID is invalid
158
The registering device’s ID is invalid
159
The caller’s device is not registered
160