Galil DMC-1700 Manual Do Utilizador

Página de 253
DMC-1700/1800 
Appendices  •  205 
 
 
Inputs 
 
Encoder, A+, B+ 
Position feedback from incremental encoder with two channels in 
quadrature, CHA and CHB.  The encoder may be analog or TTL.  Any 
resolution encoder may be used as long as the maximum frequency 
does not exceed 12,000,000 quadrature states/sec.  The controller 
performs quadrature decoding of the encoder signals resulting in a 
resolution of quadrature counts (4 x encoder cycles).  Note:  Encoders 
that produce outputs in the format of pulses and direction may also be 
used by inputting the pulses into CHA and direction into Channel B 
and using the CE command to configure this mode. 
Encoder Index, I+ 
Once-Per-Revolution encoder pulse.  Used in Homing sequence or Find 
Index command to define home on an encoder index. 
Encoder, A-, B-, I- 
Differential inputs from encoder.  May be input along with CHA, CHB 
for noise immunity of encoder signals.  The CHA- and CHB- inputs are 
optional. 
Auxiliary Encoder, Aux A+, 
Aux B+, Aux I+, Aux A-, Aux 
B-, Aux I- 
Inputs for additional encoder.  Used when an encoder on both the motor
and the load is required.  Not available on axes configured for step 
motors. 
Abort 
A low input stops commanded motion instantly without a controlled 
deceleration.  Also aborts motion program. 
Reset 
A low input resets the state of the processor to its power-on condition.  
The previously saved state of the controller, along with parameter 
values, and saved sequences are restored. 
Forward Limit Switch 
When active, inhibits motion in forward direction.  Also causes 
execution of limit switch subroutine, #LIMSWI.  The polarity of the 
limit switch may be set with the CN command. 
Reverse Limit Switch 
When active, inhibits motion in reverse direction.  Also causes 
execution of limit switch subroutine, #LIMSWI.  The polarity of the 
limit switch may be set with the CN command. 
Home Switch 
Input for Homing (HM) and Find Edge (FE) instructions.  Upon BG 
following HM or FE, the motor accelerates to slew speed.  A transition 
on this input will cause the motor to decelerate to a stop.  The polarity 
of the Home Switch may be set with the CN command. 
Input 1 - Input 8 isolated 
Input 9 - Input 16 isolated 
Input 17 - Input 24 TTL 
 
Uncommitted inputs.  May be defined by the user to trigger events.  
Inputs are checked with the Conditional Jump instruction and After 
Input instruction or Input Interrupt. Input 1 is latch X, Input 2 is latch 
Y, Input 3 is latch Z and Input 4 is latch W if the high speed position 
latch function is enabled. 
 
Latch 
High speed position latch to capture axis position on occurrence of 
latch signal.  AL command arms latch.  Input 1 is latch X, Input 2 is 
latch Y, Input 3 is latch Z and Input 4 is latch W.  Input 9 is latch E, 
input 10 is latch F, input 11 is latch G, input 12 is latch H.