INSTALLATION: 
 
THIS UNIT HAS BEEN DESIGNED TO BE INSTALLED IN MANY LOCATIONS. BECAUSE THIS UNIT IS A ZERO 
CLEARANCE FIREPLACE IT MAY BE INSTALLED IN A WOOD FRAMED COMBUSTIBLE CHASE, AS SHOWN. 
 
FRAMING DIMENSIONS: 
 
WIDTH:  
35 3/8”  (89.85 CM) 
HEIGHT: 
31 3/4”  (80.65 CM) 
 
 
(INCLUDING FINISHED HEARTH HEIGHT) 
DEPTH:  
13 3/4”  (34.93 CM) 
 
NOTE: 
When preparing framing for this unit insure that the 
framing on the outside wall or ceiling will not interfere with 
the vent pipe. Framing must maintain proper clearances to 
the unit and vent pipe. 
 
NOTE:  
Also make sure that the top header above the framing 
opening is installed on the edge or upright, this will maintain 
proper clearances to the vent pipe. 
 
 
 
 
 
 
 
 
 
 
 
NOTE:
  MAKE SURE THAT THE UNIT HAS BEEN INSTALLED SO 
THAT THE BOTTOM OF THE UNIT IS INSTALLED AT THE 
SAME HEIGHT AS THE FINISHED HEARTH HEIGHT. IF 
THE UNIT IS NOT INSTALLED IN THIS MANNER THE 
SURROUND WILL NO LONGER FIT ONTO THE UNIT. 
 
 
 
 
 
 
 
 
 
 
Once the framing has been completed remove the unit from 
its packaging and remove the top louvers and door cover by 
lifting up on the louvers and door cover and pulling outwards 
from the unit. 
 
Remove the decorative surround panel from the unit. There 
are four screws located in the four outer corners just inside 
the surround panel. (AS SHOWN on next page) 
 
 
 
 
 
 
5