THE  CONTROLLER  TO  MALFUNCTION. A  HIGH  QUALITY  POWER 
CONDITIONER MUST BE INSTALLED IF THE ABOVE CONDITIONS EXIST. 
MALFUNCTIONS CAUSED BY A POOR ELECTRICAL SUPPLY ARE NOT 
COVERED UNDER YOUR WARRANTY.
The controller is wired to the heater as shown in Figure 15.  The model and 
rating plate provides the electrical information needed to size the complete 
heater branch supply.
All electrical work must be installed in accordance with the Canadian Electrical 
Code, CSA C22.1 and local requirements.
When installed, the appliance must be electrically grounded in accordance 
with local codes or, in the absence of local codes, with the Canadian Electrical 
Code, CSA C22.1.
DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEATER TANK 
IS FILLED WITH WATER.
NOTE:  This controller is Polarity Sensitive. If the Hot and Neutral Supply 
Voltage is reversed, the controller will not sense flame. Verify polarity before 
connecting the unit.
3. This  unit  may  never  be  connected  to  any  existing  heating  system  or  
  component(s)  previously  used  with  non-potable  water  heating  
  appliance.
4. When the system requires water for space heating at temperatures higher 
than required for domestic water purposes, a tempering valve must be 
installed. Please refer to installation diagrams on pages 23 through 28 in 
back of manual for suggested piping arrangements.
HEATER WIRING
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE 
MUST  BE  REPLACED,  IT  MUST  BE  REPLACED  WITH  105°C  OR  ITS 
EQUIVALENT, EXCEPT IN THE BURNER HOUSING. IN THIS CASE USE 
200°C WIRE.
THE COMPUTER CONTROL REQUIRES A SOURCE OF  STABLE CLEAN 
ELECTRICITY FOR PROPER OPERATION. INSTALLING THE HEATER 
ON A BRANCH CIRCUIT THAT HAS ELECTRONIC NOISE, IS SUBJECT 
TO  FLUCTUATIONS  IN  VOLTAGE  LEVEL  OR  HAS AN APPLIANCE 
WHICH  GENERATES  EMF  OF  RFI  INTERFERENCE  CAN  CAUSE 
FIGURE 15.