“F” Group: Main Profile Parameters
The basic frequency (speed) profile is 
defined by parameters contained in the 
“F” Group as shown to the right. The set 
running frequency is in Hz, but accelera-
tion and deceleration are specified in the 
time duration of the ramp (from zero to 
maximum frequency, or from maximum 
frequency to zero). The motor direction 
parameter determines whether the keypad 
Run key produces a FWD or REV command. This parameter does not affect the intelli-
gent terminal [FWD] and [REV] functions, which you configure separately.
Acceleration 1 and Deceleration 1 are the standard default accel and decel values for the 
main profile. Accel and decel values for an alternative profile are specified by using 
parameters Ax92 through Ax93. The motor direction selection (F004) determines the 
direction of rotation as commanded only from the keypad. This setting applies to any 
motor profile (1st or 2nd) in use at a particular time
Output 
frequency
t
0
F002
F001
F003
“F” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF 
(EU)
–FU 
(USA)
Units
F001
Output frequency 
setting
Standard default target 
frequency that determines 
constant motor speed,
range is 0.0 / start frequency
to 400 Hz
0.0
0.0
Hz
VR      0000.0Hz
F002
Acceleration (1) time 
setting
Standard default acceleration,
range is 0.01 to 3000 sec.
10.0
10.0
sec.
ACC 1    010.00s
F202
Acceleration (1) time 
setting, 2nd motor
Standard default acceleration, 
2nd motor,
range is 0.01 to 3000 sec.
10.0
10.0
sec.
2ACC1    010.00s
F003
Deceleration (1) time 
setting
Standard default deceleration,
range is 0.01 to 3000 sec.
10.0
10.0
sec.
DEC 1    010.00s
F203
Deceleration (1) time 
setting, 2nd motor
Standard default deceleration, 
2nd motor,
range is 0.01 to 3000 sec.
10.0
10.0
sec.
2DEC1    010.00s
F004
Keypad Run key routing Two options; select codes:
00... Forward
01... Reverse
00
00
DIG-RUN      FWD