Hitachi L200 Manual Do Utilizador

Página de 280
“D” Group: Monitoring Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–8
Local Monitoring During Network Operation
The L200 inverter’s serial port may be connected to a network or to an external digital 
operator. During those times, the inverter keypad keys will not function (except for the 
Stop key). However, the inverter’s 4-digit display still provides the Monitor Mode 
function, displaying any of the parameters D001 to D007. Function B089, Monitor 
Display Select for Networked Inverter, determines the particular D00x parameter 
displayed. Refer to the table below.
When monitoring the inverter during network operation, please note the following:
• The inverter display will monitor D00x functions according to B089 setting when...
• the OPE/485 DIP switch is set to the “485” position, or
• a device is already connected to the inverter’s serial port at inverter powerup.
• During network operation, the inverter keypad will also display error codes for 
inverter trip events. Use the Stop key or inverter Reset function to clear the error. Refer 
to 
 to interpret the error codes.
• The Stop key can be disabled, if you prefer, by using function B087.
B089 Monitor Display Select for Networked Inverter
Option
Code
Monitor 
Code
Monitor Function Name
01
D001
Output frequency monitor
02
D002
Output current monitor
03
D003
Rotation direction monitor
04
D004
Process variable (PV), PID feedback monitor
05
D005
Intelligent input terminal status
06
D006
Intelligent output terminal status
07
D007
Scaled output frequency monitor