UTILITY ROUGH-IN DIMENSIONS AND POSITIONING 
 FOR PS740-SERIES OVENS
Figure 2-19.  Typical PS740-Series Oven(s)  
Installation
To Oven
To Oven
WARNING 
DO NOT USE CONDUIT FOR GROUND 
CONNECTION. 
CAUTION
IT IS RECOMMENDED THAT THE OVEN 
BE PLACED UNDER A VENTILATION  
HOOD FOR ADEQUATE AIR SUPPLY  
AND VENTILATION.
ELECTRIC SUPPLY TO BE  
PROVIDED BY CUSTOMER
CIRCUIT BREAKER
Separate circuit breaker with lockout/tagout electrical shutoff 
for each oven. Wire each oven separately.
100  Amp  circuit  breaker  for  208-240V,    or  50  Amp  circuit 
breaker for 380-480V.
ELECTRICAL SPECIFICATIONS
DOMESTIC:  208V  main  blower  motors  and  elements,  
3  Ph,  75  Amp  draw,  50/60  Hz,  208-240V  control  circuit,  
3 pole, 4 wire system per oven (3 hot, 1 grd).
Do NOT use conduit for ground.
or
DOMESTIC:  
240V  main  blower  motors  and  elements,  
3  Ph,  65  Amp  draw,  50/60  Hz,  208-240V  control  circuit,  
3 pole, 4 wire system per oven (3 hot, 1 grd).
Do NOT use conduit for ground.
or
EXPORT:  
380V  elements,  3  Ph,  41  Amp  draw,  50/60  Hz,  
208-240V  control  circuit  and  main  blower  motor,  4  pole,  
5 wire system per oven (3 hot, 1 neutral, 1 grd).
Do NOT use conduit for ground.
or
DOMESTIC:  
480V  elements,  3  Ph,  32.5  Amp  draw,  
50/60  Hz,  208-240V  control  circuit  and  main  blower  motor,  
4 pole, 5 wire system per oven (3 hot, 1 neutral, 1 grd).
Do NOT use conduit for ground.
ELECTRICAL RATING
27.0 kW/hr.
SUPPLY WIRE
Supply wire size must be in accordance with the National 
Electrical Code (current edition) and must be in compliance 
with local codes.
NOTE: The electrical terminal connection marked “MP” located 
inside the control compartment is desiganated for the blue 
(neutral) wire to the oven. See the electrical wiring/schematics 
in Section 6 of this manual.
SUGGESTED
If space permits, service should be located near the control 
console  end  of  the  oven(s)  to  allow  convenient  access  to 
safety switches. 
Suggested dimensions are shown; utility code 
requirements supersede any factors shown.