Middleby Marshall 60254 Manual Do Utilizador

Página de 36
16
P/N 60254 September 28, 2012
5.  If it is necessary to add or remove conveyor links to achieve 
the correct tension, OR if it is necessary to reverse the 
conveyor belt for correct orientation, the belt will need to 
be removed from the conveyor frame. If this is necessary, 
perform the following procedure: 
•  Remove the conveyor assembly from the oven and place 
it flat on the floor.
•  Remove the master links using long-nose pliers. Then, 
roll up the belt along the length of the conveyor frame.
•  Add or remove belt links as necessary to achieve the 
correct belt tension.
•  Replace the belt on the conveyor frame. Check that the 
conveyor belt links are oriented as shown in Figure 2-15, 
and that the smooth side of the conveyor belt faces UP.
•  Connect the inside master links. Check that the links 
are oriented as shown in Figure 2-15.
•  Connect the outside master links. Note that the outside 
master links each have an open hook on one side. This 
hook aligns with the hooks along the sides of the other 
conveyor links. See Figure 2-15.
•  Replace the conveyor into the oven.
Figure 2-15.  Conveyor and Master Link orientation 
E.  Final Assembly
1.  Install the crumb trays underneath the conveyor as shown 
in Figure 2-16. 
CONVEYOR BELT REVERSAL
Conveyor belt reversal consists of three steps:
1.  Physically reversing the conveyor belt.
2.  Resetting direction jumper on the conveyor control board.
3.   Switching the photo detector.
REVERSING THE CONVEYOR BELT
Remove the conveyor from the oven and find the master link 
location. Remove master links and remove the belt from the 
conveyor frame. Reassemble the belt back onto the frame (in 
the reverse direction) and reinstall the master links. Replace 
the conveyor assembly in the oven.
RESETTING DIRECTION JUMPER
Locate Jumper P1 on the conveyor control board. Move jumper 
from terminals 1 and 2, and replace onto terminals 2 and 3.
CAUTION:  Shock hazard in compartments electrical filters 
are electrically alive.
SWITCHING PHOTO DETECTOR
CAUTION:  Disconnect Power Before Switching Photo eye.
Remove the three screws securing the access door to the unit. 
Open the access door and disconnect the connector fitting to 
the photo eye assembly. Remove the two screws securing the 
photo eye assembly to the control box. Remove the four nuts 
securing the photo eye to the housing. Rotate the photo eye 
180 degrees and resecure the photo eye with the four nuts. 
On the opposite control box, remove the two screws holding the 
cover where the photo eye assembly will be positioned. Secure 
the photo eye assembly in position with the two screws. Place 
the photo eye cover on the opposite control box, where the 
photo eye assembly was removed, and secure the two screws. 
Secure the access door with the three screws. 
Remove the three screws securing the access door on the 
opposite side. Open the access door, where the photo eye is 
now positioned, and connect the photo eye connector fitting. 
Secure the access door with the three screws. 
Apply power to the unit. Adjust the photo eye height by loosening 
the two screws securing the photo eye assembly and sliding 
the photo eye assembly either up or down, such that the beam 
is approximately 1/4 inch above the belt.
Note:  This is MUCH easier in reduced light.
Replace all covers.
Direction
of travel
CORRECT 
master link 
position
Incorrect 
master link 
position
Figure 2-16.  Crumb Trays
Crumb tray 
insertion