Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs) 
<—ethernet—> R8si 
193
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 1.
Begin
Steps
Open the Processor Channel Assignment form — enter  
ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc                Gtwy        Interface  
 Destination      Session    Mach
Chan Enable  Appl.  To  Mode  Link/Chan   
Node 
Port  Local/Remote  ID
  1: 
_______ 
 _    __  _____  _____________  0____  ___   ___    __
  2:
 n 
_______ 
 _    __  _____  _____________  0____  ___   ___    __
  3:
_______ 
 _    __  _____  _____________  0____  ___   ___    __
  4: 
_______ 
 _    __  _____  _____________
0____  ___   ___    __
  :
21: y
 
dcs ___
c
1_  0
_ node-1a-ppp__ 5003_ 21_
12_    1_
23: y    dcs ___
c
1_  0
_ node-3_______   
5003_ 23_
32_    3_
  :    
 64:
 n 
_______ 
 _    __  _____  _____________  0____  ___   ___    __
Field
Conditions/Comments
For Processor Channel 21
: (ppp connection to Switch 1)
Enable
Set to 
y
.
Appl.
Set to 
dcs
 for DCS signaling.
Mode
Node-2 is the “client” for this session. Set node-1a to 
“server” (
s
).
Interface Link
Must match the link number assigned on the node-2 data 
module screen.
Interface Chan
A value of 
0
 allows any available interface channel to be 
used for this connection. The Destination Port number on 
the Switch-1 Processor Channel screen must also be set to 
0
.
Destination Node
Name of the far-end node for this channel. This must be a 
name entered on the Node Names screen. For ppp 
connections, it must match the Destination Node Name 
entered on the ppp Data Module screen.
Destination Port
This number must match the Interface Channel number 
assigned on the Switch-1 Processor Channel screen.
1 of 2