Справочник Пользователя для Lucent Technologies Release 8.2
Configuration 5B: R8csi <—ppp—> R8r (2 C-LANs)
<—ethernet—> R8si
<—ethernet—> R8si
193
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3
C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on
Switch 1.
Switch 1.
Begin
Steps
>
Open the Processor Channel Assignment form — enter
ch com p
> Enter values
change communications-interface processor-channels
Page 1 of X
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc Gtwy Interface
Destination Session Mach
Chan Enable Appl. To Mode Link/Chan
Node
Port Local/Remote ID
1:
n
_______
_ __ _____ _____________ 0____ ___ ___ __
2:
n
_______
_ __ _____ _____________ 0____ ___ ___ __
3:
n
_______
_ __ _____ _____________ 0____ ___ ___ __
4:
n
_______
_ __ _____ _____________
0____ ___ ___ __
:
21: y
dcs ___
c
1_ 0
_ node-1a-ppp__ 5003_ 21_
12_ 1_
23: y dcs ___
c
1_ 0
_ node-3_______
5003_ 23_
32_ 3_
:
64:
64:
n
_______
_ __ _____ _____________ 0____ ___ ___ __
Field
Conditions/Comments
For Processor Channel 21
: (ppp connection to Switch 1)
Enable
Set to
y
.
Appl.
Set to
dcs
for DCS signaling.
Mode
Node-2 is the “client” for this session. Set node-1a to
“server” (
“server” (
s
).
Interface Link
Must match the link number assigned on the node-2 data
module screen.
module screen.
Interface Chan
A value of
0
allows any available interface channel to be
used for this connection. The Destination Port number on
the Switch-1 Processor Channel screen must also be set to
the Switch-1 Processor Channel screen must also be set to
0
.
Destination Node
Name of the far-end node for this channel. This must be a
name entered on the Node Names screen. For ppp
connections, it must match the Destination Node Name
entered on the ppp Data Module screen.
name entered on the Node Names screen. For ppp
connections, it must match the Destination Node Name
entered on the ppp Data Module screen.
Destination Port
This number must match the Interface Channel number
assigned on the Switch-1 Processor Channel screen.
assigned on the Switch-1 Processor Channel screen.
1 of 2