OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
(Continued)
8. Observe  the  oil  level  indicator
light while cranking the engine.
If  the  light  is  blinking  while
cranking the engine, the oil level
may  be  low,  or  the  oil  level
system  may  be  faulty.    Contact
the engine manufacturer.
Reconnect  P4/J4  to  shut  the
engine down.
Attempt  to  start  the  engine
using  the  recoil  starter;  if  the
engine starts, check lead #212
for  faulty  insulation.    If  lead
#212  is  good,  replace  the  PC
board.
If the engine fails to start, have
the engine and oil level system
checked by a qualified engine
service technician.
The engine will not shut down.
1. Place the engine switch in the
“stop”  position  and  check  for
battery voltage at the PC board
pin  J3-10.  (lead  #211)    If
voltage is present, the switch is
defective.
2. Locate  and  ground  the
brown/white  lead  from  the
engine ignition magneto.  If the
engine still will not shut down,
the  engine  ignition  magneto
may  be  defective.    Contact  a
qualified engine technician. 
3. If the engine shuts down when
the  brown/white  lead  is
grounded,  check  wiring  and
connections  at  leads  #212,
GND-I,  GND-J,  and  the  brown
leads between connector J4/P4
and  the  engine  ignition
magneto.    If  these  leads  and
connections are good, replace
the PC board.