ALARM REC MODE SET
8
English
65
[Settings] (‹ indicates default setting.)
[Setting conditions]
z
This can be set whenever the recording rate is 10.00 
FPS or more for field recording, or 5.00 FPS or more for 
frame recording.
7
Move the cursor to “ALARM 
RECORDING” and press the [ ] button, 
then press the [
] or [
] button to 
change the setting.
[Settings] (‹ indicates default setting.)
* “DLY AL-REC ON TMR” is enabled just by making timer 
settings. There is no need to press the [TIMER] button.
8
Move the cursor to “REC RATE” and 
“DURATION” and press the [ ] button, 
then press the [
] or [
] button to 
change the setting. 
The maximum number of images (shown in parentheses) 
changes in accordance with the new settings.
[Settings]
*CC: Operates while an alarm is being activated.
Press the [EXIT/OSD] button.
The display returns to the normal screen.
“ALARM” appears in the operation display area.
When an alarm occurs, the number of alarms is displayed.
z
If a new alarm occurs during alarm recording
Recording switches from the previous alarm image to 
the new alarm image in a seamless process. If a 
number of different alarms occur, these are treated as a 
single alarm until an alarm interruption occurs.
z
Settings cannot be made for “PRE-ALARM 
RECORDING” when “ALARM RECORDING” is set to 
“OFF”.
z
The alarm history (recording list) displays up to the last 
9,999 items. (Although the history can record up to 
16,000 items, only 9,999 of these can be displayed on-
screen.)
z
When the normal recording area is set to “*1%”, alarm 
recording is performed for as long as space is left in the 
alarm recording area. For “1%” and other settings, up to 
16,000 items are recorded per hard disk.
Setting
Description
‹
OFF
Audio recording is not carried out
ON
Audio recording is carried out
Setting
Description
‹
OFF
Does not perform alarm recording.
ENABLED
Always performs alarm recording, regardless 
of whether or not timer recording is being 
performed.
AL-REC ON 
TIMER
Performs alarm recording only during timer 
recording.
AL-REC OFF 
TIMER
Performs alarm recording only when timer 
recording is not being performed.
  * DLY  AL-REC 
ON TMR
Performs alarm recording only for the amount 
of time set by the timer. Normal recording is 
not performed.
Maximum 
number of 
images
Setting
Description
REC RATE
60.00 to 0.03 FPS (for 
field recording)
30.00 to 0.02 FPS (for 
frame recording)
Sets the recording 
rate.
DURATION
1 second to 15 minutes, 
*CC
Sets the recording 
time per alarm.
When alarm recording settings have been 
completed
Number of alarm 
recordings
Alarm display
10- 20- 04 ALARM 0000
08: 30: 00 EN
10FPS