American Dryer Corp.
450260-1
Filter  Maintenance
To remove filter element: twist the filter bowl 1/8 turn clockwise
(CW).  Then pull the bowl down to expose the filter element.
To  remove  the  filter  element,  unscrew  the  baffle  (this  will
allow  element  removal).
To clean filter element use soap and water.
Note
When  replacing  the  filter  element  bowl,  care  must
be  taken  to  ensure  that  the  O-Ring  does  not  get
pinched.
Regulator  Operation
The adjustment knob simply acts upon a spring rest located
on  the  spring  and  directly  compresses  the  spring  as  it  is
adjusted.  A non-rising low torque adjustment screw is used
on this type of filter and regulator.  The upper spring rest is
located  on  top  of  the  regulator  spring  and  transmits  force
from  the  adjustment  screw  to  the  spring.    Regulators  use
simple  wire  coil  springs  for  controlling  the  downstream
regulator  pressure.    The  bonnet  houses  the  adjustment
spring  and  is  used  to  help  retain  the  diaphragm.    The
diaphragm  moves  up  when  the  downstream  pressure
reaches  its  preset  pressure  level,  which  in  turn  closes  the
valve.  A self-relieving regulator is designed to automatically
relieve overpressure in the secondary side of the regulator.
Note
This  self-relieving  feature  is  not  designed  to  bleed
the downstream pressure.
Dryer  must  be  provided  with  a  clean,  dry,  and  regulated
80 psi +/- 10 psi (5.51 bar +/- 0.68 bar) air supply (equivalent
volume = 11 cfh [0.31 cmh]).
The  regulator  should  be  set  at  80  psi  +/-  10  psi  (5.51  bar
+/- 0.68 bar).  To set pressure, pull the adjusting knob up and
either turn the knob clockwise (CW) to increase the pressure
or counterclockwise (CCW) to decrease the pressure.
The  dryer  is  equipped  with  a  pneumatically  operated  heat
reclaimer  damper,  which  when  opened,  will  recirculate
approximately fifteen percent (15%) of the dryer’s exhaust air.
The heat reclaimer dampener is closed until ignition of flame
has  been  established.    Then,  the  damper  piston  is
actuated, opening the damper and recirculating fifteen percent
(15%)  of  the  exhaust  air  back  over  the  gas  burner
and into the tumbler.  The damper remains open for the rest
of  the  drying  cycle.    On  cool  down,  the  damper  closes,
exhausting  all  of  the  13,000  cfm  which  ensures  a  fast  cool
down of the load.
Note
Gas Dryers must have a "Y" dimension of 1-3/16".
!
!
!
Varistor  (MOV  [Metal  Oxide  Varistor])
Description
The varistor (MOV) is used to suppress any inductive electrical
spikes produced by the energizing and coil voltage.
Varistor (MOV) Replacement
1. Discontinue electrical service to the dryer.
2. Loosen the screws marked A1 and A2 on the contactor.
3. Verify  that  no  additional  wires  were  inadvertently
removed.
4. Reverse above procedure to install new varistor.
Filter/Regulator Assembly ___________
The purpose of the filter is to remove bulk liquids and solid
particles from the compressed air stream.  The filter element
provides mechanical separation of solids.  Centrifugal force
inside  the  filter  bowl  separates  bulk  liquids  and  larger  solid
particles.
The  filter  consists  of  a  louver,  which  causes  a  centrifugal
spinning  action  to  separate  contaminants.   A  filter,  which
mechanically  separates  contaminants  is  also  present.    The
filter  bowl  collects  the  contaminants  and  a  baffle  prevents
turbulence from picking up contaminants at the bottom of the
bowl and returning them to the air stream.
FILTER/REGULATOR