Blower (Squirrel Cage Fan) Electrical
Components _________________________
Blower  (Squirrel  Cage  Fan)  Controls
and  Overloads
Thermal Magnetic Starter (TMS) Description
The TMS is used as a safety device to manually disconnect
the motor, thereby protecting the motor from being damaged
in a locked rotor condition.  The overload has a dial setting on
the face of the device.  To set the overload, refer to your specific
electrical diagram.  The overload is specifically designed for
motor applications.  It has a current curve built into it so the
initial high current draw by the motor will not trip the overload.
On the face of the overload there are two (2) push buttons, a
"START" and a "STOP" or a dial with “ON” (1) and “OFF” (0).
The overload must be in the "START" or “ON” mode for the
motor to run.
Thermal Magnetic Starter (TMS) Replacement
1. Discontinue electrical service to the dryer.
2. Mark L1, L2, L3 and T1, T2, T3 on the wires to the TMS
for correct reinstallation.
3. Set the amp (amphere) rating on the TMS according to
the electrical schematic supplied with your dryer.
4. To remove the thermal magnetic starter, pull the tab on
the bottom of the TMS, and lift upward.
5. To install new TMS, reverse Step # 4 through Step #2.
6. Reestablish electrical service to the dryer.
Auxiliary  Contact  Block  Description
The  auxiliary  contact  block  is  mounted  on  the  side  of  the
overload.    Its  function  is  to  sense  an  overload  trip,  thereby
triggering a safety fault which will disable the drying cycle.  A
motor overload fault message will appear on the display.
Auxiliary Contact Block Replacement
1. Disconnect electrical service to the dryer.
2. Remove the TMS from the din rail by pulling the tab on
the bottom of the contact block and lift upward.
3. Remove the two (2) wires going to the auxiliary contact
block and label for correct reinstallation.
4. There are two (2) types of auxiliary contact blocks:  one
style has a screw and the other style has a clip.  In both
styles,  disassembly  and  assembly  is  recommended
with  the TMS  in  the  "STOP"  position.   To  remove  the
style that has the screw from the TMS, simply remove
the screw.  To remove the style that has the clip, simply
push  the  clip  and  twist  the  auxiliary  contact  block  to
remove.
5. To  install  new  auxiliary  contact  block,  reverse  above
procedure (Step # 4 through Step #2).
6. Reestablish electrical service to the dryer.
8. Secure/tighten  the  bolts  from  the  motor  to  the  motor
base.
9. Reinstall the belt guard removed in Step #2.
10. Reestablish electrical service to the dryer.
Blower  Shaft  Replacement
The  procedure  to  replace  the  blower  shaft  is  the  same
procedure used to replace the shrouded pillow block bearing.
(Refer to page 22.)
Important
Make certain that the blower (squirrel cage fan) rotates
(spins) freely.
17. Reinstall the blower funnel removed in Step #7.
18. Reinstall  the  bushing  and  the  pulley  removed  in  Step
#13:    line  up  the  bushing  to  the  mark  on  the  blower
shaft,  then  secure/tighten  the  setscrew.    Reinstall  the
bolts into the original holes and tighten evenly for correct
pulley  installation.
19. Reposition  the  blower  motor  to  its'  original  position:
tighten (hand tight only) the bolts into the motor and the
motor base.  Slide the blower motor forward.  Align the
pulleys before installing the V-belts (use straight edge
to  confirm  alignment).
Important
Do not overtighten v-belts.
20. When the V-belts are properly tensioned, secure/tighten
the blower motor to the motor base.
21. Reinstall the belt guard removed in Step #2.
22. Reestablish electrical service to the dryer.
Blower  (Squirrel  Cage  Fan)
Replacement
Caution
The blower (squirrel cage fan) is located in the lint
compartment.    Properly  lock  and  tag  out  the
electrical service before entering the lint compartment.
1. Discontinue electrical service to the dryer.
2. Remove both lint drawers.
3. Remove  the  eight  (8)  1/4-20  bolts  which  secure  the
blower funnel to the blower housing assembly.
4. Remove the blower funnel.
5. Remove the two (2) left hand jam nuts and the washers.
6. Remove  the  blower  (squirrel  cage  fan)  along  with  the
3/8" x 3/8" x 3" key from the blower shaft.
Note
Install the 3/8" x 3/8" x 3" key on to the blower shaft
before installing the blower (squirrel cage fan).
7. To install new blower (squirrel cage) fan, reverse Step
#6 through Step #1.
V-Belt  Replacement
1. Discontinue electrical service to the dryer.
2. Remove the belt guard.
3. Loosen the bolts securing the blower motor to the motor
base; ease off on the tension bolt.
4. Slide the blower motor forward.
5. Remove and replace V-belts.
Note
For  proper  belt  replacement,  the  V-belts  should  be
replaced in matched sets (both belts).
6. Tighten/secure  the  tension  bolt.
Important
Do not overtighten v-belts.
7. Using a straight edge, make certain that the motor pulley
and the V-belts are properly aligned.
!
!
!
!
!
!