Справочник Пользователя для American Dryer Corp. AD-464

Скачать
Страница из 52
22
American Dryer Corp.
450260-1
19. Tighten (hand tight only) the bolts for the new motor to
the  motor  base.    Leave  enough  movement  for  V-belt
adjustment.
20. Replace  the  V-belts.    Adjust  to  proper  tension  by
adjusting  the  position  of  the  new  blower  motor.   Align
the V-belts.
21. Tighten/secure the new motor to the motor base.
22. Reconnect  the  wires  onto  the  new  motor  that  were
marked and disconnected in Step #3.  A wiring diagram
is usually affixed to the side of the motor.
23. Reinstall the belt guard removed in Step #2.
24. Reestablish electrical service to the dryer.
Shrouded Pillow Block Bearing Replacement
1. Discontinue electrical service to the dryer.
2. Remove the belt guard.
3. Loosen the bolts securing the blower motor to the motor
base.
4. Remove the V-belts from the motor pulley and the pulley
on the blower shaft.
Caution
The  blower  (squirrel  cage)  fan  is  located  in  the  lint
compartment properly lock and tag out the electrical
service before entering the lint compartment.
5. Remove both lint drawers.
6. Remove  the  eight  (8)  1/4-20  bolts  which  secure  the
blower funnel to the blower housing assembly.
7. Remove the blower funnel.
8. Remove the two (2) left hand jam nuts and the washers.
9. Remove  the  blower  (squirrel  cage)  fan  along  with  the
3/8" x 3/8" x 3" key from the blower shaft.
10. Remove the four (4) bolts securing the shrouded pillow
block bearings from the blower shaft mount.
11. Remove  the  complete  blower  shaft  assembly  with  the
shrouded pillow block bearings from the dryer.
12. To remove the shrouded pillow block bearing from the
blower (squirrel cage fan) side.  Loosen the setscrews
from the shrouded pillow block bearing.  Clean the blower
shaft  prior  to  removal  of  the  shrouded  pillow  block
bearing.
13. To remove the shrouded pillow block bearing from the
pulley  side  of  the  blower  shaft,  the  pulley  must  be
removed first.  Remove the bolts from the bushing.  Insert
the bolts into the threaded holes.  Mark the inside of the
blower  motor  shaft  before  removing.    Loosen  the
setscrews  on  the  bushing.    Remove  the  bushing  and
the pulley.
14. To  remove  the  shrouded  pillow  block  bearing:    loosen
the  setscrew  from  the  shrouded  pillow  block  bearing.
Clean  the  blower  shaft  prior  to  the  removal  of  the
shrouded  pillow  block  bearing.
15. Replace the shrouded pillow block bearing on the blower
shaft:    secure  the  blower  shaft  to  the  blower  shaft
bearing  mount.    Tighten/secure  the  setscrews  in  the
shrouded  pillow  block  bearing.
Note
Install the 3/8" x 3/8" x 3" key on to the blower shaft
before installing the blower (squirrel cage fan).
16. Reinstall the blower (squirrel cage fan) removed in Step
#9.
!
!
10. Remove  the  bushing.
11. Measure the mark on the motor’s shaft (from Step #8) to
the end of the shaft and mark the new motors' shaft.
12. Install new blower on to the motor base.
13. Slide  the  motor  pulley  on  to  the  new  blower  motors'
shaft.
14. Slide the bushing onto the shaft until the inside of the
bushing  meets  the  mark  (from  Step  #11)  on  the  new
motor’s  shaft.
15. Tighten/secure  the  setscrews  into  the  bushing.
16. Insert the bolts into the large holes on the bushing and
thread them into the motor pulley.
17. Tighten the bolts evenly for motor pulley installation.
18. Align the pulleys.
MAN3286
PULLEY INSTALLATION
MAN3286
PULLEY REMOVAL
MAN2343