INSTALLATION CHECKLIST 
 
BEFORE PLACING DOOR OPERATOR IN REGULAR SERVICE, MAKE SURE THAT: 
  
1. THE FRONT AND REAR MOUNTS FOR THE OPENER ARE SOUND AND SECURE AND 
THE RAIL IS POSITIONED CORRECTLY ABOVE THE HIGH ARC OF THE DOOR, AND 
THAT THE OPENER IS POSITIONED OVER THE DOOR ACTION CENTERLINE. 
2. FOR SECTIONAL DOORS AND ONE-PIECE DOORS WITH TRACKS, THE POSITION OF 
THE DOOR ARM, WITH THE DOOR CLOSED, IS SUCH THAT ITS CONNECTING POINT 
ON THE TROLLEY IS 5" TO 8" BEHIND ITS CONNECTING POINT ON THE DOOR 
BRACKET.  THE DOOR ARM SHOULD NEVER BE PERFECTLY VERTICAL WHEN THE 
DOOR IS IN THE CLOSED POSITION.  
3. FOR ONE-PIECE DOORS WITHOUT TRACKS, THE POSITION OF THE DOOR ARM, 
WITH THE DOOR CLOSED, IS SUCH THAT ITS CONNECTING POINT ON THE 
TROLLEY IS 30" TO 32" BEHIND ITS CONNECTING POINT ON THE DOOR BRACKET.   
4. THE EMERGENCY RELEASE HANDLE AND CORD ARE SECURE TO THE 
EMERGENCY RELEASE LEVER.  THE HANDLE IS LOCATED 6 FT ABOVE  FLOOR 
LEVEL AND REQUIRES NO MORE THAN 50 LBS. PULL TO ACTUATE.  THE TROLLEY 
AND RELEASE MECHANISM ARE PROPERLY LUBRICATED.  
5. THE STANDARD WALL PUSH BUTTON OR THE DELUXE WALL PUSHBUTTON 
STATION IS IN SUCH A POSITION AND OF SUCH A HEIGHT THAT IT CAN ONLY BE 
ACTUATED BY AN ADULT OF AVERAGE HEIGHT.  THE CAUTION LABEL IS 
PROMINENTLY DISPLAYED NEXT TO THE PUSH BUTTON OR WALL STATION.  
6. ALL WIRING IS CORRECT TO CODES OR BETTER.   THERE IS GROUND CONTINUITY 
IN THE SUPPLY.  THE GROUND PRONG ON THE POWER CORD IS INTACT.  
7. ALL ROPES HAVE BEEN REMOVED FROM THE DOOR.  THE DOOR MOVES FREELY 
WITHOUT BINDING WHEN RAISED OR LOWERED MANUALLY.  THE DOOR IS 
CORRECTLY BALANCED AND LUBRICATED.  ALL DOOR HARDWARE IS SECURE 
AND SOUND.  THE SENSITIVITY HAS BEEN ADJUSTED TO MINIMUM FORCE FOR 
THE APPLICATION.  
8. THE DOOR REVERSES ON OBSTRUCTIONS TO WITHIN 1-1/2" OF THE FLOOR.  THE 
CONCRETE OR OTHER SURFACE BENEATH THE CLOSED DOOR PROVIDES 
UNIFORM CONTACT.  
9. THE PLASTIC ENVELOPE FOR THIS MANUAL IS ATTACHED TO THE WALL NEAR 
THE PUSH BUTTON OR WALL STATION AND THIS MANUAL IS PLACED THERE FOR 
OWNER USE AND REFERENCE.   
10. ON DOORS WITH EXTENSION TYPE COUNTERBALANCE SPRINGS, RESTRAINT 
CABLES HAVE BEEN INSTALLED THROUGH THE SPRINGS.  
11. THERE IS GFI PROTECTION ON THE LINE TO POWER THE OPENER OR IN THE 
RECEPTACLE.  THIS IS PARTICULARLY IMPORTANT ON INSTALLATIONS 
INVOLVING DOORS OF STEEL CONSTRUCTION.  
12. ON DOORS WITH ADJUSTABLE BOTTOM EDGES, LOCK EDGES  HAVE BEEN 
LOCKED AFTER ADJUSTMENT