Справочник Пользователя для Emerson Process Management Rosemount

Скачать
Страница из 4
Product Specification Sheet
00815-0100-4810, Rev AA
June 2005
2
Overview
This Product Specification sheet defines the 
requirements for the Conditioning Orifice Plate 
(COP). This Specification is also included for 
Electronic Pressure Instruments when integrated 
with the Conditioning Orifice Plate (COP) primary to 
form complete flowmeters.
Vendor Requirements
The manufacturer of the COP shall be certified to the 
international standard ISO 9001.
The vendor shall have the ability to pre-assemble the 
COP primary with a pressure instrument 
(transmitter), perform a leak-test and calibrate the 
unit before shipping.
The vendor shall have the ability to provide technical 
support for the COP primary element and the 
pressure instrument.
When a pressure instrument is supplied with the 
COP, each pressure instrument shall be individually 
tested for accuracy using calibration equipment 
traceable to NIST or an equivalent internationally 
recognized authority.
Instrument Specifications
The COP shall perform within ± 0.5% to ± 0.75% of 
discharge coefficient (dependant on conditioning 
orifice beta size) and the vendor shall make 
independent testing documentation available 
demonstrating this performance.
The COP shall have the ability to accommodate 
isolation valves and connections that are suitable for 
connecting a pressure instrument.
All line sizes serviced by the COP shall be able to 
accommodate a remote RTD.
Conditioning Orifice Plate 
The COP shall consist of four symmetrical orifice 
holes to allow flow separation independent of flow 
rate, pressure or temperature. As a result, a flow 
coefficient (Cd) shall be maintained over a wide 
range of Reynolds numbers.
These products shall deliver accurate and repeatable 
results when installed downstream of a variety of flow 
disturbances, that normally cause measurement 
errors in the flow process.
Materials
The primary element shall be available in 316 
Stainless Steel, 304L Stainless Steel, Monel
®
 and 
Hastelloy
®
 276 material types.
The COP shall be available for use with industry 
standard flanges:
ANSI B16.5 (FF, RF, RTJ)
ANSI B16.36 Orifice Flange Unions
(FF, RF, RTJ)
DIN EN.1092 (FF, RF)
DIN 19214 Orifice Flange Unions (FF, RF)
The COP material will be the same or equivalent to 
that of the Flange Unions.
Conditioning Orifice Type 
The COP will be configured as either a Compact 
Orifice Plate design or as an Orifice Plate design. 
Both designs will have four symmetrical orifice holes 
with a specific beta size depending on the process 
application. 
Compact Conditioning Orifice Plate
Shall be of all-welded design
Shall be capable of withstanding 1440 psig at 
100°F (99 bar at 38°C)
Shall be capable of installing between ANSI 
Flange Unions
Shall have a centering mechanism for 
installation in center of pipe
Shall be capable of direct mounting to the 
pressure instrument 
Conditioning Orifice Plate
Shall be of Paddle type or Universal Type
Shall be capable of withstanding 6000 psig at 
100°F (408 bar at 38°C)
Shall be capable of installing between Orifice 
Flange Unions
Flowmeter Specifications
The vendor shall be able to supply the COP primary 
integrated with the pressure instrument to create a 
complete flowmeter.
The vendor shall have the ability to provide a 
flowmeter for both volumetric and mass flow 
output.