360 DVS Series Direct Vent Fireplaces
10006326
A hearth is not mandatory; however, for aesthetic 
purposes, we recommend installing a noncombustible 
hearth that projects out 12” (305mm) or more from the 
front of the fireplace.
Cold climate installation recommendation:  
When installing this unit against a noninsu-
lated exterior wall or chase, it is mandatory 
the outer walls be insulated to conform to 
applicable insulation codes.  
Hearth
Final Finishing
1.  Choose the unit location.
2.  Place the unit into position and secure it to the floor 
with 1¹⁄₂” (38mm) screws or nails. Holes to secure 
the unit to the floor are located behind the access 
door grille on the left and right sides of the unit.
3.  Frame in the fireplace with a header across the top. 
It is important to allow for the finished wall face when 
setting the depth of the frame.
4.  Drywall (sheetrock) or wood material may be placed 
with a zero clearance to the top edges of the appli-
ance when finishing walls above sides of the appli-
ance with glass windows. NOTE:  Attach wall finish-
ing to constructed frame, not the appliance.
5.  On 360DVSL and 360DVSR, drywall, wood, or wood 
molding may be placed with zero clearance to the 
rear wall of the unit, along the vertical edge formed 
by the standoffs, to intersection of the rear wall, to 
the side wall having the small glass window. NOTE:  
Attach wall finishing to constructed frame, not 
the appliance.
Framing & Finishing
Noncombustible materials such as brick or tile may be 
extended over the edges of the face of the appliance. 
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 
brick or tile will have to be installed flush with the edges 
of the appliance.
 
 
 
 
 
Max. 
Min.
 
 
 
 
 
Input 
Input
 
Model 
Fuel 
Gas Control 
BTU/h 
BTU/h
  360DVS2RN 
Nat 
Millivolt 
38,000 
26,600
  360DVS2RP  Prop 
Millivolt 
38,000 
28,500
  360DVS2EN 
Nat 
24V Hi/Lo 
38,000 
26,600
  360DVS2EP  Prop 
24V Hi/Lo 
38,000 
28,500
  360DVS3RN 
Nat 
Millivolt 
38,000 
26,600
  360DVS3RP  Prop 
Millivolt 
38,000 
28,500
  360DVS3EN 
Nat 
24V Hi/Lo 
38,000 
26,600
  360DVS3EP  Prop 
24V Hi/Lo 
38,000 
28,500
  360DVSLRN 
Nat 
Millivolt 
38,000 
26,600
  360DVSLRP  Prop 
Millivolt 
38,000 
28,500
  360DVSRRN  Nat 
Millivolt 
38,000 
26,600
  360DVSRRP  Prop 
Millivolt 
38,000 
28,500
Gas Specifications
Gas Inlet & Manifold Pressures
   
Natural 
LP (Propane)
 
Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
Input ratings are shown in BTU per hour and are 
certified without deration for elevations up to 
4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, 
installations must be in accordance with the 
current ANSI Z223.1/NFPA 54 and/or local codes 
having jurisdiction. 
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations 
above 4,500 feet (1,370 m).
When purging the gas lines, the window 
frame assembly must be removed.
The gas pipeline can be brought in through the vent 
end of the fireplace as well as the bottom. Knockouts  
(to allow gas pipe installation and testing any gas con-
nection) are provided on the bottom behind the valve. 
It is most convenient to bring the gas line in from the 
vent end of the valve, as this allows fan installation or 
removal without disconnecting the gas line.
The gas line connection can be made with properly 
tinned 3/8” copper tubing, 3/8” rigid pipe, or an ap-
proved flex connector. Since some municipalities have 
additional local codes, it is always best to consult your 
local authority and the CSA-B149.1 installation codes.
For USA installations, consult the current National Fuel 
Gas Code, ANSI Z223.1/NFPA 54.  
Always check for gas leaks with a mild 
soap and water solution. Do not use an 
open flame for leak testing.
The gas control is equipped with a captured-screw type 
pressure test point, therefore it is not necessary to pro-
vide a 1/8” test point upstream of the control.