Справочник Пользователя для Majestic Appliances 360DVS2

Скачать
Страница из 44
11
360DVS Series Direct Vent Fireplaces
10006326
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY 
7/1/98
1/2” Gas Supply
1/2” NPT X 1/2” Flare Shut-Off Valve
3/8” Flex Line
(From Valve)
FP297a
Fig. 5  Gas shutoff valve and flex connector.
When using copper or flex connector, use only ap-
proved fittings. Always provide a union when using 
black iron pipe so that the gas line can be easily discon-
nected for burner or fan servicing. Refer to the gas 
specification for pressure details and ratings. 
Isolate or disconnect this or any other gas appli-
ance control from the gas line when pressure test-
ing.  
DO NOT subject the fireplace valve to test 
pressures exceeding 1/2 psi. 
EB-1 Electrical Junction Box Connection
The fireplace, when installed, must be 
electrically connected and grounded in ac-
cordance with local codes; in the absence 
of local codes, use the current CSA C22.1 
Canadian Electrical Code.
For USA installations, follow the local 
codes and National Electrical Code  ANSI/
NFPA No. 70.
It is strongly suggested the wiring of the 
EB-1 Electrical Junction Box be carried out 
by a licensed electrician.
Ensure power to the supply line has been 
disconnected before commencing with this 
procedure.
The EB-1 electrical junction box has been supplied 
standard on this model to allow for easy connection of 
the optional fan kits. (Fig. 6)
To connect the EB-1 box to the house electrical supply 
follow the steps below.
1.  Remove the front cover of the EB-1 box.
2.  Remove the plug socket assembly from the EB-1 
box.
3.  Feed the supply line in from the out through the elec-
trical knockout.
4.  Connect the ground wire of the supply line to the 
green screw of the socket assembly.
5.  Connect the white wire of the power line to the 
chrome screw of the socket assembly.
6.  Connect the black wire of the power supply line to 
the brass screw (polarized) of the socket assembly.
FP1428
EB-1 location
Electrical 
Inlet Hole
Gas Inlet 
Hole
EB-1 Electrical box Depend-
ing on the specific model, 
this box may be installed on 
either side of the appliance.
FP1428
Fig. 6  EB-1 attachment.
Remote ON/OFF Switch Installation
Do not wire the remote ON/OFF wall switch 
for this gas appliance into a 120V power 
supply.
1.  Thread the wiring through the holes on the end 
panels of the appliance. Take care not to cut the wire 
or insulation on metal edges. Route the wire to a 
conveniently located receptacle box.
2.  Attach the wire to the ON/OFF switch and install the 
switch into the receptacle box.
3.  Connect the other ends of the wire to the gas control 
valve, as shown in Figure 7.
TP
TH
TP
TH
FP1429
remote switch wiring
7/05
Remote ON/OFF Switch
Gas 
Control 
Valve
FP1429
Fig. 7  Remote switch wiring diagram for R models.
Alternate Switch Location
The remote switch can be installed on the front or the 
side of the access door. Simply mount the switch to the 
bracket provided and screw the bracket to either side 
of the frame, lining up the screws with the prepunched 
holes. (Fig. 8)
7.  Refit the socket assembly back into the electrical 
box and replace the cover plate. 
8.  The EB-1 electrical junction box is now ready to sup-
ply power to the FK12 or FK24 fan kit, if used.