360DVS Series Direct Vent Fireplaces
10006326
Electronic Gas Control Valve
This appliance may be fitted with a Honeywell ignition 
module. 
Installation of the remote ON/OFF starter switch on 
electronic ignition units
 (Fig. 12): 
1.  Thread the wiring through the holes on the side 
panels of the appliance. Take care not to cut the wire 
or insulation on metal edges. Route the wire to a 
conveniently located receptacle box.
2.  Attach the wire to the ON/OFF switch and install the 
switch into the receptacle box.
3.  Connect the white wire from the wall switch to the 
black wire from the transformer, using an approved 
wire nut. Connect the black wire from the wall switch 
to the black wire running from the #6 position of the 
ignition module, also using an approved wire nut.
PILOT
HONEYWELL IGNITION MODULE
ORANGE
BLUE
BLACK
WHITE
NOVA SIT 822 VALVE
HI
LO
POWER CORD
W/FEMALE SPADE
120 VAC RTN
WHITE
GREEN
BLACK
120 VAC HOT
BLACK
YELLOW
24 VAC RET
40VA TRANSFORMER
24 VAC HOT
BLACK
WHITE
WALL SWITCH
WHITE
OFF
1    2    3          5    6    8     9
 MV      MV/VP   PV                    GRD      24V     SENSE   SPARK
24V
ORANGE
RED
GREEN
BLACK
FP1225
Fig. 12  Honeywell ignition module.
Your fireplace is approved to be vented either through 
the side wall, or vertically through the roof.
• 
Only CFM Corporation venting components, specifi-
cally approved and labeled for this fireplace, may be 
used.
• 
Venting terminals shall not be recessed into a wall or 
siding.
• 
Horizontal venting must be installed on a level plane 
without an inclining or declining slope.
There must not be any obstruction such as bushes, 
General Venting
garden shed, fencing, deck or utility building within 24” 
(610mm) from the front of the termination hood.
Do not locate the termination hood where excessive 
snow or ice buildup may occur. Be sure to check the 
vent termination area after snow falls; clear it to prevent 
accidental blockage of the venting system. When using 
a snow blower, make sure snow is not directed toward 
the vent termination area. 
Location of Vent Termination
It is imperative the vent termination be located observ-
ing minimum clearances as shown on the following 
page.