LDVR Series Direct Vent Gas Fireplace
10007317
The fireplace, when installed, must be 
electrically connected and grounded in 
accordance with local codes or, in the ab-
sence of local codes, with the current CSA 
C22.1 Canadian Electrical Code.
For USA installations follow local codes 
and the national electrical code  ANSI/
NFPA No. 70.
It is strongly suggested that the wiring of 
the EB-1 Electrical Junction Box be carried 
out by a licensed electrician.
Ensure that the power to the supply line 
has been disconnected before commenc-
ing this procedure.                
The EB-1 Electrical junction box has been fitted stand-
ard on this model to allow for the easy connection of an 
optional fan kit. 
To connect the EB-1 box to the house electrical supply 
follow the steps below.
1.  Unscrew the retaining screw from the EB-1 base 
plate and remove the EB-1 assembly from the  
appliance. (Fig. 8)
2.  Remove the front cover of the EB-1 box.
3.  Remove the plug socket assembly from the EB-1 
box.
4.  Feed the supply line in through the EB-1 opening in 
the side of the appliance and then through the back 
of the EB-1 assembly. (Fig. 8)
5.  Connect the black wire of the power supply line to 
the brass screw (polarized) of the socket assembly.
6.  Connect the white wire of the power line to the 
chrome screw of the socket assembly.
7.  Connect the ground wire of the supply line to the 
green screw of the socket assembly.
8.  Refit the socket assembly back into the electrical 
box and replace the cover plate. Secure the cable 
with the clamp on the outside of the EB-1 base 
plate and refit the EB-1 assembly to the unit with the 
screw removed in step 1.
This appliance may be fitted with a Synetek ignition 
module. 
Installation of the remote on/off starter switch or 
wall thermostat on electronic ignition units. 
1.  Thread the wiring through the holes on the side 
panels of the appliance. Take care not to cut the wire 
or insulation on metal edges. Route the wire to a 
conveniently located receptacle box.
2.  Attach the wire to the ON/OFF switch and install the 
switch into the receptacle box.
3.  Connect the white wire from the wall switch or wall 
thermostat to the white wire terminal from the elec-
tronic module. Connect the black wire from the wall 
switch or the red wire from the wall thermostat, to 
the red wire terminal from the electronic module.
Electronic Gas Control Valve
EB-1 Electrical Box
FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97
OUTSIDE
������������
INSIDE
BACK OF UNIT
FP580
Electrical Box
Retaining Screw
Fig. 8  EB-1 receptacle.