LDVR Series Direct Vent Gas Fireplace
10007317
Installation
1.  Thread the wiring through the holes on the end 
panels of the fireplace. Take care not to cut the wire 
or insulation on metal edges. Route the wire to a 
conveniently located receptacle box.
2.  Attach the wire to the ON/OFF switch and install the 
switch into the receptacle box.
3.  Connect the other ends of the wire to the gas control 
valve. (Fig. 6) 
The gas pipeline can be brought in through the rear 
of the appliance as well as the bottom. Knockouts are 
provided on the bottom behind the valve to allow for the 
gas pipe installation and testing of any gas connection. 
It is most convenient to bring the gas line in from the 
rear right side of the valve as this allows fan installation 
or removal without disconnecting the gas line.
The gas line connection can be made with properly 
tinned 3/8” copper tubing, 3/8” rigid pipe or an ap-
proved flex connector. Since some municipalities have 
additional local codes, it is always best to consult your 
local authority and the National Fuel Gas Code, ANSI 
Z223.1/NFPA 54 in the USA or the CSA-B149.1 instal-
lation code.
Do not wire the remote ON/OFF wall switch 
for the gas fireplace to the 120  volt power 
supply.
Alternate Switch Location
The remote switch can be installed on the front/side 
of the access door. Simply mount the switch to the 
bracket provided and screw the bracket to either side 
of the frame, lining up the screws with the pre-punched 
holes. (Fig. 7)
The gas control is equipped with a captured screw type 
pressure test point, therefore it is not necessary to pro-
vide a 1/8” test point up stream of the control.
When using copper or flex connector use only approved 
fittings. Always provide a union when using black iron 
pipe so the gas line can be easily disconnected for 
burner or fan servicing. See gas specification for pres-
sure details and ratings.
The fireplace valve must not be subjected to any test 
pressures exceeding 1/2 psi. Isolate or disconnect this 
and any other gas appliance control from the gas line 
when pressure testing. 
Gas Line Installation
Remote ON/OFF Switch
When purging the gas lines, the front win-
dow frame assembly must be removed.
Always check for gas leaks with a mild 
soap and water solution. Do not use an 
open flame for leak testing.
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY 
7/1/98
FP297A
1/2” Gas Supply
1/2” NPT x 1/2” Flare Shut-
off Valve
3/8” Flex Line
(From Valve)
Fig. 5  Typical gas supply installation.
FP1024
alternate
remote switch
location
1/27/00   djt
FP1024
Fig. 7  Alternate switch location.
TP
TH
TP
TH
FP1224
Remote switch
11/02
Remote ON/OFF Switch
or Thermostat
or Remote Control
Gas 
Control 
Valve
FP1224
Fig. 6  Remote switch wiring diagram.