Справочник Пользователя для Majestic Appliances 33LDVR

Скачать
Страница из 40
6
LDVR Series Direct Vent Gas Fireplace
10007317
    
 
 
Max. 
Min.
    
 
 
Input 
Input
  Model 
Fuel  Gas Control  BTU/h  BTU/h
  33LDVRRN  Nat 
Millivolt 
16,000  11,200
  33LDVRRP  Prop 
Millivolt 
16,000  12,000
  33LDVREN  Nat 
24V Hi/Lo 
16,000  11,200
  33LDVREP  Prop*  24V Hi/Lo 
16,000  12,000
  36LDVRRN  Nat 
Millivolt 
19,500  13,650
  36LDVRRP  Prop 
Millivolt 
19,500  14,625
  36LDVREN  Nat 
24V Hi/Lo 
19,500  13,650
  36LDVREP  Prop*  24V Hi/Lo 
19,500  14,625
  39LDVRRN  Nat 
Millivolt 
23,000  16,100
  39LDVRRP  Prop* 
Millivolt 
22,500  16,875
  39LDVREN  Nat 
24V Hi/Lo 
23,000  16,100
  39LDVREP  Prop*  24V Hi/Lo 
22,500  16,875
  43LDVRRN  Nat 
Millivolt 
26,000  18,200
  43LDVRRP  Prop* 
Millivolt 
24,000  18,000
  43LDVREN  Nat 
24V Hi/Lo 
26,000  18,200
  43LDVREP  Prop*  24V Hi/Lo 
24,000  18,000 
Noncombustible materials such as brick or tile may be 
extended over the edges of the face of the fireplace. 
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 
brick or tile will have to be installed flush with the edges 
of the fireplace.
Final Finishing
Gas Specifications
33LDVR / 36LDVR / 39LDVR / 43LDVR
Certified To
ANSI Z21.88b-2003 / CSA  2.33b-2003
Vented Gas Fireplace Heaters
Framing and Finishing 
  Inlet Minimum 
5.5” w.c. 
11.0” w.c.
  Inlet Maximum 
14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
Gas Inlet and Manifold Pressures
 
Natural 
LP (Propane)
High Elevations
Input ratings are shown in BTU per hour and are 
certified without deration for elevations up to 
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, 
installations must be in accordance with the cur-
rent ANSI Z223.1/NFPA 54 and/or local codes hav-
ing jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370m).
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance:
1.  Choose the location.
2.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 
1/2” drywall while flange “B” is for 5/8” drywall.
3.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in  
place.
FP1544
nail flange
1/05
Fig. 4  Nailing flanges.
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
Flange Location for 
Desired Drywall Depth
FP1539
A
B
33LDVR units: GFRN2I0, GFRL2I0, GFRE2I0
36LDVR units: GFRN2J0, GFRL2J0, GFRE2J0
39LDVR units: GFRN2K0, GFRE2K0
43LDVR units: GFRN2N0, GFRE2N0
*Using conversion kit