Справочник Пользователя для Procom EL250RYLB-O

Скачать
Страница из 21
  1 4
TROUBLESHOOTING
ODS/pilot  lights  but  flame is continuous
igniting and the main burner couldn’t be
lit.
1.  Thermocouple  connection  loose
at  control  board
2.    Pilot  flame  not  touching thermcouple
       which  allows thermocouple  to  cool,
       causing  pilot  flame  to  go  out.  This
       problem  could  be  caused  by  one or
       both of the following
       A)   Low  gas  pressure
       B)  Dirty  or  partially  clogged ODS/
             pilot
3.   Thermocouple  damaged
4.   Control  valve  damaged
1 .     H a n d   t i g h t e n   t h e   c o n n e c t o r s .
2.  A) Contact local propane/LP gas
company.
     B)  Clean ODS/pilot (see Cleaning
and Maintenance, page 12) or replace
ODS/pilot  assembly
Burner does not light after  ODS/pilot   is
lit
1.    Burner  orifice  clogged
2.   Inlet  gas  pressure  is  too  low
3.   Burner  orifice  diameter  is  too  small
4.   Thermocouple  leads  disconnected
      or improperly connected
5.   Burners  will  not  come  in remote
      position
1 . C l e a n   b u r n e r   ( s e e   C l e a n i n g
      and   Maintenance
, page 12) or  replace
      burner orifice.
2.  Contact    local     propane/LP    gas
      company
3.   Replace  burner  orifice
4.   Reconnect    leads (see   wiring  diagram)
5.  Replace  battery  in  transmitter  and
      receiver
3.    Replace  thermocouple
4.    Replace  control  valve
REMEDY
     WARNING:Make sure that power is
turn off before proceeding....
       WARNING:  Turn off  and let cool
before servicing. Only a  qualified  ser-
vice  person  should service and repair
fireplace.
       CAUTION: Never use a wire,
needle, or similar object  to clean
ODS/pilot. This  can  damage  ODS/
pilot  unit.
When   pressing the button of ignitor   but-
ton  is  pressed, there  is   spark at ODS/
pilot but  no  ignition
OBSERVED  PROBLEM
POSSIBLE CAUSE
1.   Gas   supply   turned   off   or   equipment
      shut off  valve closed
2.  Air in gas lines when installed.
3.   Depleted gas supply
4.  ODS/pilot  is  clogged
5.   Gas regulator setting is not correct
6.  Pilot electrude position is not correct
7. Wire is not correct or loosen
8 Gas valve is damage
1 .     T u r n   o n   g a s     s u p p l y     o r     o p e n
 equipment shutoff valve
2.
3. Contact    local    propane/LP   gas
  company
4    Clean    ODS/pilot (see   Cleaning and
       Maintenance,page 12 ) or replace
      ODS/pilot  assembly
5.   
   Replace  gas  control
6.   Replace Pilot
7.   Check the wine and make wine correct.
8.   Replace gas valve
No spark when press in ignition button
1. No power to heater
2. No battery in transmitter or battery isn’t
correctly assembly
1. Check the electric power
2. Place or replace the battery.
Press ON/OFF button  again
     until air    is removed  .