Справочник Пользователя для Procom EL250RYLB-O

Скачать
Страница из 21
1 5
SPECIFICATIONS
Btu                                                            20,000/25,000                              20,000/ 25,000
Gas
 Type
                                                       LP Gas                                      Natural Gas
Ignition                                                         Automatic                                      Automatic
Manifold   Pressure                                          8"W.C.                                         3"W.C.
Inlet  Gas  Pressure
(In. of water)*
       Maximum                                                   14"                                             10.5"
       Minimum                                                    11"                                                5"
Dimensions, Inches (H×W×D)
       Stove                                                                   38 3/16”×26 3/8”×14 1/8”
       Carton                                                                  40 1/8”×29 5/16”×15 5/16”
Weight, lbs
       Stove                                                                                     78
       Shipping                                                                                 94
       voltage                                                     120                                            120
       watt
                                          27
                                    27
*For purposes of input adjustment
   EL250RYLB-O
   EN250RYLB-O
Delayed   ignition  burner
1.   Manifold  pressure  is  too  low
2.   Burner orifice clogged
1.   Contact   local  gas company
2.  Clean  burner (see Cleaning  and
       Maintenance, 
page 12)
Burner  backfiring  during  combustion
1.   Damaged burner
2.   Gas  regulator  defective
1.   Clean  burner  orifice  (see  Cleaning
       and  Maintenance
, page 12)
2.   Replace  gas  regulator
Slight   smoke   or   odor   during  initial
operation
1.   Residues  from  manufacturing
       processes
2.   Not enough air
3.   Gas  regulator defective
1.   Problem  will stop after a few hours
      of operation
2.   Check  burner  for  dirt  and  debris.
       If  found, clean  burner (see Cleaning
       and  Maintenance
, page 12)
3.   Replace  gas  regulator
Dark  residue  on logs  or  inside  of
fireplace
1.   Improper  log  placement
2.   Air holes at burner inlet blocked
3.   Burner flame holes blocked
1.  Properly locate logs (see installing
logs,  page  21)
2.   Clean out air holes at burner inlet.
Periodically  repeat  as  needed.
3.   Remove blockage or replace burner
Heater  produces  a   clicking/ticking
noise  just  after  burner  is  lit  or  shut off
1.  Metal    expanding   while  heating
       or  contracting  while  cooling
1.  This is common with most heaters. If
     noise  is  excessive, contact  qualified
     service person
TROUBLESHOOTING
Continued