DEHUMIDIFYING OPERATION (continued)
Auto 
Dehumidifying
Operation mode
In this situation
Operating mechanism
• In damp 
weather
• In most of the cases, the room temperature at the time the button is 
pressed becomes the preset temperature.
  (When room temperature is below 12°C, set 13°C. When it is 
13°C~22°C, set +2°C. When it is below 23°C~26°C, set room 
temperature. When it is above 26°C, set 26°C) 
•  Target humidity is around 50~60%. If the humidity becomes lower than 
the target value, operation stops. If it becomes higher than the target 
value, operation resume.
• The operation mode may automatically be switched to cooling or 
heating for temperature control. (Refer to table below) 
• To dry the 
laundry 
quickly
• Detects outdoor temperature, room temperature and humidity to 
automatically select the most suitable combination of heating and 
powerful dehumidifying operations.
•  This operation is performed together with stainless plasma air purifying 
operation.
• Priority is given to laundry drying.
  Be sure use this mode when no one is in the room as the room 
temperature and humidity will be high temporarily. 
• 3-hour timer function is used for this operation mode.
• When 
controlling 
condensation 
formed on 
windows in 
winter time
• To control the condensation, priority is given to the operation for 
lowering humidity. Therefore, the room temperature goes down in 
this operation mode. The operation stops if the room temperature 
becomes 1°C or below. 
• 2-hour timer function is used for this operation mode.
Condensation 
Control
Quick Laundry
• Be careful when condensation control operation is performed if the outside temperature is low as it will lower the 
room temperature. 
   (OFF TIMER) and   (ON TIMER) (page 26), which are to be set using clock function, are not available during 
dehumidifying (quick laundry and condensation control modes) operation. However, the timer (for 30 minutes 
and 1-9 hours) can be set for quick laundry and condensation control modes with the 
 (SLEEP) button. 
• To set to your desired temperature and humidity while executing dehumidifying, it is recommended to use manual 
dehumidifying function. (Page 17)
• If you do not wish room temperature to be too high when drying the laundry, use the preference (Powerful) mode 
instead of quick laundry mode. (Page 18)
The operation mode may automatically be switched to cooling or heating for temperature control.
At this time, the room humidity may vary by approximately 10%.
Heating
operation
Dehumidifying operation
Operation
stop
Cooling 
operation
About 3
°
C
Approx. 3°C if outside temp. is 
below approx. 32°C.
Approx. 1°C if outside temp. is 
above approx. 32°C.
Room temperature set
Current room temperature
1ºC
COOLING OPERATION
Press the 
 (COOL) button to start cooling operation.
Press the 
 (COOL) button.
•  Adjust the room temperature and fan speed to your preference.
  Temperature range between 16°C~32°C can be set.
Press the 
 (STOP) button.
•  A short beep sounds and cooling operation stops.
STOP