SOLAR CONTROLLER AND SOLAR MONITOR 
2007 October 
SK6203 Rev B 
DIAGNOSTIC FEATURES OF THE SOLAR CONTROLLER 
The operational modes are: 
 
 
Flashes Operational 
Modes 
solid green 
(remains on) 
Standby mode 
green 
slow pulse 
Standby mode 
(power on for less than 48 hours) 
green 
rapid pulse 
Circulating water through collectors 
3 x green 
Circulating water through collectors 
(power on for less than 48 hours) 
no green 
(remains off) 
Power outage or call for service 
 
 
Flashes Fault 
Modes 
red 
rapid pulse 
Temperature rise across collector greater than 40°C 
(circulator at full speed) 
3 x red 
Hot sensor in collector – short circuit 
4 x red 
Hot sensor in collector – open circuit 
5 x red 
Cold sensor –short circuit 
6 x red 
Cold sensor – open circuit 
 
 
If the power supply to the solar control unit is on and the green LED is off or the 
red LED is flashing, this indicates there may be a fault with the water heater. 
The red LED may emit up to six flashes in each series of flashes. 
 
Note: During periods of high solar radiation and if the circulator activates after 
having been off, such as during start up, it is possible the red LED may emit a 
rapid pulse for a period of up to ten (10) minutes. This does not indicate a fault. 
Refer to 
 
If the red LED continues to emit a rapid pulse for longer than ten (10) minutes, 
or emits a series of flashes, then count the number of flashes and phone your 
nearest Service Department or Accredited Service Agent to arrange for an 
inspection.