ABOUT YOUR WATER HEATER 
 
MODEL TYPE 
Congratulations for choosing a Rheem
®
 water heater. Your Rheem solar 
Loline™ water heater is designed for the solar collectors to be roof mounted 
and the solar storage tank to be installed at ground level. The solar storage 
tank is suitable for outdoor installation only and can be installed with Rheem 
NPT 200 solar collectors. The system is not suitable for installation above 
400 metres altitude. 
 
The system when installed in areas subject to freeze conditions must be 
installed with the solar hot and solar cold pipes fully insulated with closed cell 
polymer insulation (minimum thickness 13 mm) to offer protection against 
freeze damage. Freeze conditions occur below 6
°C. The system has NO 
WARRANTY for freeze damage when installed above 400 metres altitude or if 
the solar hot and solar cold pipes are uninsulated (refer to 
 on page 59 and to 
 
HOW HOT SHOULD THE WATER BE? 
The solar control unit will circulate 
water through the solar collectors until 
a temperature of approximately 75
°C is 
reached. During periods of low solar 
energy gain, the water temperature can 
be boosted by the thermostatically 
controlled gas burner. The boosting is 
controlled by both the timer unit and the 
gas control thermostat. 
 
The water heater features a user 
adjustable thermostat, which allows you 
to personally choose the most suitable 
boosting temperature for your hot water 
needs. Refer to 
 
To meet the requirements of the 
National Plumbing Standard the 
temperature of the stored water must 
not be below 60
°C. Rheem 
recommends the thermostat is set at 
60
°C to maximise solar contribution. 
 
 
typical maximum 
temperature 
maximum booster setting 
minimum recommended 
stored water temperature 
maximum recommended 
supply temperature to 
bathrooms and ensuites