SAVE A SERVICE CALL 
12 
CAN’T LIGHT THE PILOT FLAME 
• 
Is there gas to the water heater? 
Check the gas isolation valve on the 
gas supply line is open. 
• 
Is there a normal gas supply to the 
rest of the premises? 
Try lighting another gas appliance to 
check. If there is no gas, call the gas 
supplier. 
 
TEMPERATURE PRESSURE RELIEF VALVE RUNNING 
• 
Normal Operation 
It is normal and desirable this valve 
allows a small quantity of water to 
escape during the heating cycle. 
However, if the discharge is deemed 
excessive (more than 2% of hot water 
used), there may be another problem. 
• 
Continuous dribble 
Try gently raising the easing lever on 
the relief valve for a few seconds 
(refer to 
“Temperature Pressure 
Relief Valve”
 on page 9). This may 
dislodge a small particle of foreign 
matter and clear the fault. Release 
the lever gently. 
• 
Steady flows for long period (often 
at night) 
This may indicate the mains water 
pressure sometimes rises above the 
designed pressure of the water 
heater. Ask your installing plumber to 
fit a pressure limiting valve. 
 
NEVER replace the relief valve with one of a higher pressure rating. 
• 
Heavy flows of hot water until the water heater is cold - then stops 
until water reheats 
The gas control must be turned off using the knob on top of the gas control 
thermostat (refer to 
“Close Down Procedure”
 on page 36). Phone your 
nearest Rheem Service Department or Accredited Service Agent to arrange 
for inspection.