Справочник Пользователя для Mitsubishi Electronics MR-J2S- CP

Скачать
Страница из 357
 
 
15 -  27 
15. COMMUNICATION FUNCTIONS 
 
15.12.8 Test operation mode 
(1) Instructions for test operation mode 
The test operation mode must be executed in the following procedure. If communication is interrupted 
for longer than 0.5s during test operation, the servo amplifier causes the motor to be decelerated to a 
stop and servo-locked. To prevent this, continue communication without a break, e.g. monitor the 
status display. 
(a) Execution of test operation 
1) Turn off all input devices. 
 
2) Disable the input devices. 
Command Data 
No. 
Data 
[9][0] [0][0] 
1EA5 
 
3) Choose the test operation mode. 
Command  Data No. 
Transmission data 
Selection of test operation mode 
[8][B] 
[0][0] 
0000 
Test operation mode cancel 
[8][B] [0][0] 
0001  Jog 
operation 
[8][B] [0][0] 
0002  Positioning 
operation 
[8][B] [0][0] 
0003  Motor-less 
operation 
[8][B] 
[0][0] 
0004 
DO forced output 
 
4) Set the data needed for test operation. 
 
5) Start. 
 
6) Continue communication using the status display or other command. 
 
(b) Termination of test operation 
To terminate the test operation mode, complete the corresponding operation and. 
1) Clear the test operation acceleration/deceleration time constant. 
Command Data 
No. 
Data 
[A][0] [1][2] 
1EA5 
 
2) Cancel the test operation mode. 
Command Data 
No. 
Data 
[8][B] [0][0] 
0000 
 
3) Enable the disabled input devices. 
Command Data 
No. 
Data 
[9][0] [1][0] 
1EA5