15 -  29 
15. COMMUNICATION FUNCTIONS 
 
(c) Start of positioning operation 
Transmit the speed and acceleration/deceleration time constant, turn on the servo-on (SON) and 
forward/reverse rotation stroke end (LSP LSN), and then send the moving distance to start 
positioning operation. After that, positioning operation will start every time the moving distance is 
transmitted. To start opposite rotation, send the moving distance of a negative value. 
When the servo-on (SON) and forward/reverse rotation stroke end (LSP LSN)  are off, the 
transmission of the moving distance is invalid. Therefore, positioning operation will not start if the 
servo-on (SON) and forward/reverse rotation stroke end (LSP LSN) are turned on after the setting 
of the moving distance. 
 
(d) Temporary stop 
A temporary stop can be made during positioning operation. 
Command Data 
No. 
Data 
[A][0] [1][5] 
1EA5 
 
Retransmit the same communication commands as at the start time to resume operation. 
To stop positioning operation after a temporary stop, retransmit the temporary stop 
communication command. The remaining moving distance is then cleared.