Справочник Пользователя для Mitsubishi Electronics MR-J3

Скачать
Страница из 668
 
 
16 -  20 
16. INDEXER POSITIONING OPERATION 
 
(2) Write instruction codes 
Set the data, which was requested to be written with the instruction code 8010h to 91FFh. 
Set the instruction code No. corresponding to the item to Instruction code (RWwn 2) and the written data 
to Writing data (RWwn 3). The codes and answer data are all 4-digit hexadecimal numbers. 
When the instruction code which has not been described in this section is set, the error code (
1 ) is 
stored in respond code (RWrn 2). 
 
Code No. 
Item 
Writing data (RWwn 3) contents 
(Programmable controller   Servo amplifier) 
8010h 
Alarm reset command 
Deactivates the alarm that occurred. 
1EA5 
8101h 
Feedback pulse value display data is clear 
Resets the display data of the status 
indication "feedback pulse value" to 0. 
1EA5 
8200h 
Parameter group write command 
Writes the group of parameters that are 
written to with codes No.8201h to 82FFh and 
8301h to 83FFh. 
Writes the group of parameters that are read 
with codes No.0201h to 02FFh and 0301h to 
03FFh. 
Parameter group
0: Basic setting parameters (No.PA        )
1: Gain/filter parameters (No.PB        )
2: Extension setting parameters (No.PC        )
3:  I/O setting parameters (No.PD        )
0 0 0
 
8201h 
to 
82FFh 
Data RAM instruction of parameter 
Writes the set value of each No. of the 
parameter group written by code No.8200h to 
RAM. These values are cleared when power 
is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the 
parameter No. 
An error code is returned if an instruction 
code outside the range set in parameter No. 
PA19 or a value outside the setting range of 
the corresponding parameter is written. 
Convert the decimal values into hexadecimal before setting. 
8301h 
to 
83FFh 
Data EEP-ROM instruction of parameter 
Writes the set value of each No. of the 
parameter group written with code No.8200h 
to EEP-ROM. Written to EEP-ROM, these 
values are held if power is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the 
parameter No. 
An error code is returned if an instruction 
code outside the range set in parameter 
No.PA19 or a value outside the setting range 
of the corresponding parameter is written. 
Convert the decimal values into hexadecimal before setting. 
8601h 
to 
86FFh 
Motor speed of point table 
Writes the motor speeds of point table No.1 to 
255 to RAM. These values are cleared when 
power is switched off. 
The decimal value converted from the 2 lower 
digits of the code No. corresponds to the point 
table No. 
Convert the values into hexadecimal before setting.